6.

Test procedure

1.
Connect the main power cable.
2.
Turn on the machine.
3.
Bring the machine to Standby.
4.
Activate the pump from the MMI as follows:
a.
b.
5.
Verify that the motor and pulley are working properly and that there are no
strange noises.
6.
Click Vac. Pump again in the MMI to turn off the pump.
7.
If the motor and the pulley are working properly, reinstall the compressor
compartment cover using the original two screws.
8.
Reinstall the paper exit tray.
9.
If the motor or pulley is not working properly, perform the following:
a.
b.
Danger:
The main power cable must remain disconnected while working on the pump or
motor.
c.
d.
e.
f.
7.

Parts list

N/A
8.

Materials disposition

Discard old pump pulley.
9.

Attached documents

N/A
Proprietary and Confidential
Pulley replacement only for presses operating at 60Hz frequency
From the Diagnostics menu select Elements and click the Elements
tab.
For the Substrate category, click Vac. Pump.
The pump begins to operate.
Turn off the machine.
Disconnect the main power cable.
Reinstall the pulley and belt per the procedure in this kit.
Reverify that the motor and pulley are working properly per steps 1
through 6 above.
Reinstall the compressor compartment cover using the original two
screws.
Reinstall the paper exit tray.