Si121292EC
Step
4
Disconnect the
connector [S80] and
pull out the clamp.
5
Disconnect the 4
connectors for the
electronic expansion
valve coil and pull out
the clamp.
6
Disconnect the
connector [S93] and
pull out the clamp.
Removal Procedure
Procedure
[S20] [S21] [S22] [S23]
[S93]
[S80]: four way valve coil
[S80]
The cooling only models
have no harness for [S80].
Clamp
(R11187)
[S20] (white): room A
[S21] (red): room B
[S22] (blue): room C
[S23] (yellow): room D
5-room models also have
[S24] (green) for room E.
Clamp
When reassembling, insert
each clamp into the hole.
For the electronic
expansion valve coil
(R20765)
[S93]: liquid pipe thermistor
Clamp
(R10400)
Electrical Box
Points
For [S93]
(R17904)