(TROUBLE 2) Oven seems to be operating but little heat is produced in oven load.
CONDITION
Output is low
NOTE : Simple test of power output-conducted by heating one liter water for one min. if available.
Minimum 8.5¡C temperature rise is normal condition.
CHECK
Check the
power source
voltage.
Measure the
output power.
RESULT
Lower than 90% of
rating voltage.
Normal
Abnormal
5-13
CAUSE
Decrease in power
source voltage
with load.
Defective
magnetron.
REMEDY
Suggest customer
contact local
electric power
utility co. or
qualified
electrician.
Replace
magnetron.