30 electrolux
Connection in Ducting Version
When installing the ducting version,
connect the hood to the chimney using
either a fl exible or rigid pipe ø 150 or
125 mm, the choice of which is left to
the installer.
EN
To install a ø 150
• To install the dumper 10a.
• Fix the pipe in position using suffi cient
pipe clamps (not supplied).
To install a ø 125
• To install a ø 125 mm air exhaust con-
nection, insert the reducer fl ange 9 on
the dumper 10a.
• To install the Adapting ring 10b.
• Fix the pipe in position using suffi cient
pipe clamps (not supplied).
• Remove any activated charcoal fi l-
ters.
Connection in Recycling Version
• Connect the fl ange to the outlet on
the shelf over the hood using a fl exible
or rigid pipe (ø120 or 150 mm).
• To install a ø 120 mm air exhaust con-
nection, insert the reducer fl ange 9 on
the hood body outlet.
• Fix the pipe in position using suffi cient
pipe clamps (not supplied).
• Ensure that the activated charcoal fi l-
ters have been inserted.
Electrical Connection
• Connect the hood to the mains
through a two-pole switch having a
contact gap of at least 3 mm..
Installation
ø 150
10a
ø 125
10b
9
10a
ø120
9 9