3. Before starting

Installation of your canned motor pump is:
• fixed with a fixed pipe, or
• fixed with a flexible hose.
Take care
When installing it is necessary to take care that the pump
is never fitted hanging from its delivery pipe, but is always
placed in a raised position with respect to the bottom of the
well so that the muddy bottom is not sucked up with the
water.
Never handle or hang the pump by gripping the power
supply cable.
In pumps with a floating switch, the latter is adjusted in
order to make immediate starting possible.
Note
The pump well must have minimum dimensions of
40 x 40 x 50 cm so that the floating switch can move freely.
It is also possible to use round, prefabricated concrete
wells with an inner diameter of approx. 40 cm.

4. Maintenance instructions

Your canned motor pump is a quality product, free from
maintenance. It has been subjected to rigorous final
checks.
However, for a long service life and continuous operation,
we recommend constant care and regular checks.
• Before every maintenance job, disconnect the plug.
• For transportable use the pump should be washed with
clear water after every use.
• For fixed installation it is recommended to check the
operation of the floating switch every 3 months.
• Using a jet of water, get rid of the fibre and spindly particles
that may get deposited in the pump's casing.
• In the event of excessive deposits in the pump casing,
dismantle the inlet filter by unscrewing the star screw.
Wash the pump casing and fit the inlet filter back on.
• Every 3 months remove the mud from the bottom and
walls of the well.
• Eliminate the deposits from the floating switch, washing it
with fresh water.
• Protect the pump from frost.
ENGLISH
CAUTION!
"DRAINAGE"
Special instructions: It is not suitable for pumping:
sewage, sandy water.
The pump must never run dry.
The manufacturer's warranty is null and void in the
event of damage to the pump caused by it running
dry.
"VORTEX"
The pump must never run dry.
The manufacturer's warranty is null and void in the
event of damage to the pump caused by it running
dry.
CAUTION:
Never use gasoline, benzine, thinner, alcohol or the like
for cleaning. Discoloration, deformation or cracks may
result.