Page 1
All manuals and user guides at all-guides.com Z-L220 SERVICE MANUAL BASIC TAPE MECHANISM : ZZM-2 PR1NM COMPACT DISC STEREO SYSTEM BASIC CD MECHANISM : BZG-5 ZD3N1M REMOTE SYSTEM SPEAKER CASSEIVER CONTROLLER Z-L220 CX-ZL220 SX-ZL220 RC-ZAS02 • This Service Manual is the “Revision Publishing” and replaces “Simple Manual”...
All manuals and user guides at all-guides.com SPECIFICATIONS Main unit CX-ZL220 <General> Power requirements 120 V/ 220-230 V/ 240 V <FM tuner section> (switchable) 50/60 Hz Tuning range 87.5 MHz to 108 MHz Power consumption 80 W Usable sensitivity (IHF) 13.2 dBf Dimensions of main unit 360 x 395.3 x 348.8 mm...
All manuals and user guides at all-guides.com PROTECTION OF EYES FROM LASER BEAM DURING SERVICING This set employs laser. Therefore, be sure to follow carefully CAUTION the instructions below when servicing. Use of controls or adjustments or performance of proce- dures other than those specified herin may result in WARNING!! hazardous radiation exposure.
All manuals and user guides at all-guides.com NOTE ON BEFORE STARTING REPAIR 1. Forced discharge of electrolytic capacitor of power supply block When repair is going to be attempted in the set that uses relay circuit in the power supply block, electric potential is kept charged across the electrolytic capacitors (C101, 102) even though AC power cord is removed.
Page 5
All manuals and user guides at all-guides.com In such a case, check also if the POWER AMPLIFIER circuit or power supply circuit has any abnormalities or not. 2-2. Regarding reset There are cases that the machine does not work correctly because the MICROCOMPUTER is not reset even though the AC power cord is re-inserted, or the software reset (pressing the STOP key + POWER key) is performed.
All manuals and user guides at all-guides.com ELECTRICAL MAIN PARTS LIST REF. NO. PART NO. KANRI DESCRIPTION REF. NO. PART NO. KANRI DESCRIPTION 87-010-247-080 CAP, ELECT 100-50V 87-010-430-080 CAP, ELECT 100-63 8B-MA6-615-010 C-IC,LC866560-5T63 87-A12-062-080 CAP,E 100-10 SMG 87-A21-831-010 IC,SPS-422-1-F1 87-012-286-080 C-CAP, U 0.01-25 87-A21-419-040 C-IC,NJM14558MD-TE2...
Page 7
All manuals and user guides at all-guides.com REF. NO. PART NO. KANRI DESCRIPTION REF. NO. PART NO. KANRI DESCRIPTION C402 87-A12-083-080 CAP,E 0.1-50 SMG C816 87-A12-086-080 CAP,E 0.47-50 SMG C403 87-012-193-080 C-CAP,U 82P-50 CH C821 87-A12-091-080 CAP,E 10-50 SMG C404 87-012-193-080 C-CAP,U 82P-50 CH C823...
Page 8
All manuals and user guides at all-guides.com REF. NO. PART NO. KANRI DESCRIPTION REF. NO. PART NO. KANRI DESCRIPTION L832 87-005-847-080 COIL,2.2UH(CECS) C210 87-018-117-080 CAP,TC-U 68P-50 SL L902 88-ZA1-602-110 COIL,FM-RF-U2 2G C211 87-A11-147-080 CAP,TC U 0.047-50 Z F L903 88-ZA1-601-010 COIL,FM-RF-U1 2G C212 87-010-404-040...
All manuals and user guides at all-guides.com CHIP RESISTOR PART CODE Chip Resistor Part Coding Figure Resistor Code Value of resistor Chip resistor Dimensions (mm) Wattage Type Tolerance Symbol Resistor Code Form 1/16W 1005 0.35 1/16W 1608 0.45 1/10W 2125 1.25 0.45 1/8W...
All manuals and user guides at all-guides.com IC BLOCK DIAGRAM 19 ...
Page 20
All manuals and user guides at all-guides.com IC DESCRIPTION LC866560-5T63 Pin No. Pin Name Description PLL IC clock output. DATA PLL IC data output. TU-ON Tuner supply control. H: ON O-PLL-CE Tuner PLL IC chip enable. O-RMT Record ON/OFF control. H: ON BIAS Recording bias control.
Page 21
All manuals and user guides at all-guides.com Pin No. Pin Name Description NON-ECO/ P10 ECO OFF input (Connected to VSS). 75~76 P9~P8 Not used. O-KEYSCAN Output keyscan. 78~80 P6~P4 Not connected. CD SUBQ CD SUBQ serial data input. CD DRF CD DRF input.
Page 22
All manuals and user guides at all-guides.com ADJUSTMENT – 1 <TUNER/FRONT> < TUNER SECTION > 1. Clock Frequency Check 8. Output Level Check Settings : • Test point : TP2 (CLK) <AM> Method : Set to AM 1710kHz and check that the test point is Settings : •...
Page 23
All manuals and user guides at all-guides.com ADJUSTMENT – 2 <DECK> < DECK SECTION > 1. Tape Speed Adjustment (DECK 1) 5. REC/PB Frequency Response Adjustment (DECK 1) Settings : • Test tape : TTA–100 Settings : • Test tape : TTA–602 •...
All manuals and user guides at all-guides.com CD TEST MODE 1. How to Activate CD Test Mode While pressing and holding the function button, insert the AC plug. When the test mode starts, the message, “CD TEST” appears on the display. 2.
All manuals and user guides at all-guides.com TAPE MECHANISM PARTS LIST 1 / 1 REF. NO. PART NO. KANRI DESCRIPTION REF. NO. PART NO. KANRI DESCRIPTION 1 8Z-ZM1-254-310 SPR-C,REEL R 36 8Z-ZM1-220-110 LEVER,REC SENSOR 2 8Z-ZM1-225-110 GEAR,REEL R 37 8Z-ZM1-249-210 SPR-T,FR 3 8Z-ZM1-253-210 SPR-C,AUTO SENSOR...
All manuals and user guides at all-guides.com GENERAL SPEAKER DISASSEMBLY INSTRUCTIONS (FOR REFERENCE) Type.1 Type.4 Insert a flat-bladed screwdriver into the position indicated by the TOOLS arrows and remove the panel. Remove the screws of each speaker 1 Plastic head hammer unit and then remove the speaker units.
Page 31
All manuals and user guides at all-guides.com 2–11, IKENOHATA 1–CHOME, TAITO-KU, TOKYO 110, JAPAN TEL:03 (3827) 3111 2000068 9630472 0251431 Printed in Singapore...