  • Page 1 USER'S MANUAL TEMPERATURE MONITORING G2S-T...
  • Page 2 1. Introduction The G2S-T module allows easy control of any device by a NO (normally-open) relay contact. It can be used to control, for example, barrier gates, overhead doors and similar devices via a mobile phone. The maximum relay contact load is 240V/2A. In addition, in the temperature monitoring mode, the module can monitor two temperatures using the resistance thermometers connected to its inputs IN1 and IN2.
  • Page 3 SIM card. Any mobile phone can be used for this. With the power supply off, insert the prepared SIM card into the G2S-T module. The card insertion method is shown on the side of the module. The card should be pushed in until it clicks and remains in the slot.
  • Page 4 the instructions and run the utility program after the installation is complete. 5.2. The Main Application Window In this window, the tabs show data from the connected devices. In the upper part, there is the main menu. and in the lower part, there is a status bar informing about the connection status and ongoing processes.
  • Page 5 USB port. To limit the current consumption from the USB port and to avoid potential collisions while writing data from the USB port to the G2S-T memory, logging the module to the GSM network is blocked while the USB port is connected, even when the module is powered from the AC adapter.
  • Page 6 Output settings The G2S-T module output relay settings are shown in the middle-upper part of the program window. These settings are as follows:  Pulse output (monostable) – With this option, one pulse of the set duration appears on the module output after ringing from the authorized phone number. According to the set logic of its switching, the relay switches on or off for the set period of time.
  • Page 7 Other settings In the right part of the program window, you can set the operation of the G2S-T module in the event of a power failure. In the event of a power failure, the module is powered from its built-in accumulator and after the set Blackout notification delay, the module notifies the selected number of users of the power failure.
  • Page 8 7. Control of the Connected Device You can use the G2S-T module to control almost any device. Typically, it is a gate, overhead doors or barrier gate. It can be another appliance if the permissible load of the output relay contacts is not exceeded.
  • Page 9 For example, when using both thermometers and exceeding the set temperature T1 of 15.0ºC, the alarm message may have the following form: G2S-T ALARM: T1 = 15.8 deg.C(  15.0) T2 = 8.0 deg.C(  10.0) PWR = OK. Authorized users whose phone numbers are stored in the module can check the monitored temperatures via SMS.
  • Page 10 11. Operation and Maintenance of the G2S-T Module The G2S-T module may only be used under the conditions described in this manual. Otherwise, no warranty will be provided. The manufacturer shall not be liable for any damages caused by the use of the device other than as stated in the manual.
  • Page 11: Warranty Conditions

    14. Package Contents G2S-T module AC power supply adapter, output 12V/1A DC Temperature sensor 10kΩ (ß = 3435), 2pcs Connection cable USB A – mini USB 5pin B, length 1,8m...
  • Page 12: Technical Support