Download Print this page
Sealey LSTART810 Instructions

Sealey LSTART810 Instructions

Li-ion jump starter/power pack 810a 12v

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
IMPORTANT: BEFORE USING THIS PRODUCT, PLEASE READ THE INSTRUCTIONS CAREFULLY. MAKE CAREFUL NOTE OF SAFETY INSTRUCTIONS, WARNINGS
AND CAUTIONS. THIS PRODUCT SHOULD ONLY BE USED FOR ITS INTENDED PURPOSE. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY CAUSE DAMAGE
AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. RETAIN THESE INSTRUCTIONS FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
 WARNING! RISK OF EXPLOSIVE GASES. Working in the vicinity of a lead acid battery is dangerous because they can
generate explosive gases. It is important to remember that batteries generate explosive gases during normal operation.
Read and understand the general safety and operating instructions before use. The following information is intended to help you
keep the product in top working order.
NOTE – The batteries in this unit are consumable items and their ability to accept charge will reduce over time. We will warranty
against mechanical and electrical defect for a period of one year - this does not cover fair wear and tear.
If the batteries are not properly charged before first use, or regularly conditioned, their capacity will diminish. Under these circumstances we
will not replace the batteries even if it is less than one year old.
You can help prolong the lifecycle of the batteries by following a few simple guidelines.
Plug in your new LSTART to the mains transformer and make an INITIAL charge lasting 24 hours.
Ensure the unit is fully charged before storage.
DO NOT leave the LSTART for longer than 3 months without putting it on charge.
DO NOT drop or roughly handle the LSTART – this will break or disconnect the battery terminals rendering the battery useless and the
warranty void.
DO NOT use any other charger, other than the one supplied, to recharge the battery.
IMPORTANT: To reduce the risk of a battery explosion, follow these
instructions and those published by the battery manufacturer and the
manufacturer of any equipment you intend to use in the vicinity of the
battery. Remember to review warning marks on all products and on
engines.
1.1. PERSONAL PRECAUTIONS
Ensure there is another person within hearing range, or close
enough to come to your aid should a problem arise, when
working near a lead-acid battery.
Have fresh water and soap nearby in case battery acid contacts
skin, clothing or eyes.
Wear safety eye protection and protective clothing. Avoid
touching eyes while working with a battery.
Wash immediately with soap and water if battery acid contacts
skin or clothing. If acid enters eye, flush eye immediately with
cool, clean running water for at least 15 minutes and seek
immediate medical attention.
Remove personal metallic items such as rings, bracelets,
necklaces and watches. A lead-acid battery can produce a
short-circuit current high enough to weld a ring or the like to
metal, which may cause severe burns.
Always ensure that you keep clear of parts within the engine
bay which will move when the engine starts: drive belts and
pulleys for instance.
DO NOT smoke or allow a spark, or flame in the vicinity of the
battery or engine.
DO NOT drop any metal item onto the battery as it may spark
or short circuit the battery, which could cause an explosion.
1.2. IMPORTANT SAFETY INSTRUCTIONS
Familiarise yourself with the applications, limitations and potential
hazards of the LSTART .
Keep the unit in good working order and condition. Replace
damaged parts immediately.
Use only recommended parts. To use unapproved parts may be
dangerous and will invalidate your warranty.
The LSTART must only be opened and checked by qualified
service personnel. DO NOT disassemble the unit for any reason.
Keep children and unauthorised persons away from the work area.
Keep work area clean and tidy and free from unrelated materials.
Ensure that there is adequate lighting.
If the LSTART receives a sharp knock or blow, it must be
checked by a qualified service agent before further use.
© Jack Sealey Limited
IMPORTANT WARRANTY INFORMATION: KEEP YOUR LSTART HEALTHY
Original Language Version
INSTRUCTIONS FOR:
LI-ION JUMP STARTER/POWER PACK
810A 12V
LSTART810
MODEL NO:
DO NOT use LSTART to recharge dry cell batteries that are
commonly used with home appliances. These batteries may
explode and cause personal injury and damage to property.
DO NOT charge or boost a frozen battery.
DO NOT use attachments other than those recommended. To
do so may risk damage to the unit and other equipment and possible
personal injury.
DO NOT pull or carry the unit by its cables and do not pull the
negative and positive clamps from the battery terminals.
DO NOT operate in vicinity of flammable liquids or gases.
DO NOT recharge the unit with plugs, cables or attachments
that are damaged. Replace such items immediately.
DO NOT use this product to perform a task for which it is not
designed.
DO NOT store the unit in damp or wet locations or where the
temperature may exceed 40°C.
DO NOT submerge the unit in water.
DO NOT use whilst under the influence of drugs, alcohol or
intoxicating medication.
DO NOT leave the unit in a totally discharged state for an
extended period of time as this may result in permanent damage.
Place on charge at least once every 3 months.
D O NOT cross-connect the power leads from the LSTART to
the battery. Ensure that positive is to positive and negative is to
negative.
Ensure that the unit is fully charged before storage.
1.3. ELECTRICAL SAFETY (with respect to mains chargers)
WARNING! It is the user's responsibility to check the following:
You must check the AC adaptor to ensure that it is safe before
using. You must inspect the power supply lead, plugs and all
electrical connections for wear and damage. You must ensure
the risk of electric shock is minimised by the installation of
appropriate safety devices. An RCCB (Residual Current Circuit
Breaker) should be incorporated in the main distribution board.
We recommend that an RCD (Residual Current Device) is used
with all electrical products. It is particularly important to use an
RCD with portable products that plug into an electrical supply
not protected by an RCCB. If in doubt consult a qualified
electrician. You can obtain a Residual Current Device through
your Sealey dealer. You must read and understand instructions
concerning electrical safety.
LSTART810
Issue No: 1 -16/09/13

Advertisement

loading

Summary of Contents for Sealey LSTART810

  • Page 1 LSTART810 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: BEFORE USING THIS PRODUCT, PLEASE READ THE INSTRUCTIONS CAREFULLY. MAKE CAREFUL NOTE OF SAFETY INSTRUCTIONS, WARNINGS AND CAUTIONS.
  • Page 2 The range includes three models starting with the LSTART235 (Max. 235A), LSTART405 (Max. 405A) and the professional LSTART810 (Max. 810A). All units are fitted with a USB socket for powering or charging a variety of small electronic devices including mobile phones, MP3 players and tablet PCs. The LSTART810 is aimed at the professional user and is also fitted with a 12V accessory socket and a 12V EOBD plug, so the unit can act as a memory saver during vehicle diagnostics. All units come supplied with AC 12V 1A Charger and 12V accessory socket and in-vehicle charger lead.
  • Page 3 4.4.4. 12V: Similarly, the unit can provide a 12V DC output up to an 8A maximum. 4.4.5. Insert the accessory plug into the 12V outlet (fig.2.4) and press the power button. 4.5. Memory Saver Function: 4.5.1. The LSTART810 can also be used as a Memory Saver to keep various codes and settings alive whilst a vehicle battery is disconnected. 4.5.2. Ensure that there is sufficient power in the LSTART before connecting. 4.5.3. Connect the EOBD connector (fig.4.4.a) to the EOBD diagnostic socket on the vehicle. This is usually to be found in the vacinity of the steering wheel. If in doubt, consult the vehicle manufacturer's handbook for the location.
  • Page 4: Environmental Protection

    If not used regularly, it is recommended that the LSTART is recharged at least every 3 months;. 5.3. DO NOT attempt to open the casing; there are no user-servicable parts inside. If repairs are needed, return to the supplying Sealey dealer.