General Characteristics; Power Consumption; Electrical Specifications; Hydraulic Circuit - Fujitsu Waterstage WOYG160LJL Installation Manual

Air to water heat pump split single service, refrigerant r410a inverter, outdoor/hydraulic unit
Hide thumbs Also See for Waterstage WOYG160LJL:
Table of Contents

Advertisement

General characteristics

Model name
Rated heating performances (outdoor temp. / flow temp.)
Heat output
+7°C/+35°C - Underfloor heating system
-7°C/+35°C - Underfloor heating system
+7°C/+55°C - Radiator
-7°C/+55°C - Radiator

Power consumption

+7°C/+35°C - Underfloor heating system
-7°C/+35°C - Underfloor heating system
+7°C/+55°C - Radiator
-7°C/+55°C - Radiator
Coefficient of performance (COP)

Electrical specifications

Electrical voltage (50 HZ)
Maximum current for appliance
Nominal current
Maximum current of the Heating system electrical backup
Power of the Heating system electrical backup
Circulation pump actual power consumption
Maximum power consumed by the outdoor unit

Hydraulic Circuit

Maximum operating pressure
Available heating pressure at nominal point +7°C / +55°C (Δt8)
Minimum allowed hydraulic flow rate
Miscellaneous
Weight of outdoor unit
Noise level at 5 m
(Outdoor unit)
1
Sound power level in accordance with EN 12102
Weight of hydraulic unit (empty / full of water)
Hydraulic unit water capacity
Noise level at 1 m
(Hydraulic unit)
1
Sound power level in accordance with EN 12102
Heating system operating limits
Outdoor temperature min/max
Max. heating water flow temperature underfloor heating
Max. heating water flow temperature low temperature radiator
Min. flow water temperature
Refrigeration circuit
Gas pipe diameters
Liquid Piping Diameters
Factory fill of refrigerant R410A
Maximum operating pressure
Minimum / Maximum length of pipes
Maximum length of pipes
5
Maximum level difference
(Outdoor unit over hydraulic unit and heating only / Other cases)
Sound pressure level at (x) m from the appliance, 1.5m off the ground, open field
1
directionality 2.
The sound power level is a laboratory measurement of the emitted sound power. It
2
does not correspond to a measurement of the perceived sound power.
Waterstage / Installation / 2011 - EN
(Outdoor unit)
2
(Hydraulic unit)
2
3
4 / 6
Waterstage SHP
16
kW
16.00
kW
14.50
kW
14.50
kW
10.90
kW
3.86
kW
5.27
kW
5.58
kW
5.89
(+7°C/+35°C)
4.15
V
230
A
28
A
17.2
A
26.1
6 kW
kW
(single phase)
W
39.5
W
6300
MPa (bar)
0.3 (3)
MPa (bar)
0.05 (0.5)
l/h
600
Kg
137
dB (A)
45
dB (A)
67
Kg
53 / 75
l
30
dB (A)
37
dB (A)
45
°C
-25 / +35
°C
45
°C
60
°C
8
Inches
5/8
Inches
3/8
g
3800
MPa (bar)
4.15 (41.5)
m
5 / 15
m
30
m
25 / 15
Refrigerant R410A as per NF EN 378.1 standard.
3
Filling with refrigerant R410A is done at the factory.
4
Taking into account a possible additional fill of refrigerant R410A (see
5
filling", page
28).
The announced thermal and acoustic performances are measured with 7.5m length
6
refrigerant lines.
TRI 15
TRI 17
15.00
17.00
13.20
15.00
13.20
15.00
13.20
14.20
3.46
4.10
4.55
5.32
4.77
5.49
6.77
7.40
4.33
4.15
400
400
14
14
6.43
7.4
39
39
9 kW
9 kW
(3-phase)
(3-phase)
39.5
39.5
6770
7400
0.3 (3)
0.3 (3)
0.055 (0.55)
0.045 (0.45)
600
600
138
138
45
45
67
67
53 / 75
53 / 75
30
30
37
37
45
45
-25 / +35
-25 / +35
45
45
60
60
8
8
5/8
5/8
3/8
3/8
3800
3800
4.15 (41.5)
4.15 (41.5)
5 / 15
5 / 15
30
30
25 / 15
25 / 15
"Additional
- 7 -