Philips 8000 Series Service Manual page 25

Chassis q551.1e
Hide thumbs Also See for 8000 Series:
Table of Contents

Advertisement

Service Modes, Error Codes, and Fault Finding
Mute all sound outputs via softmute
Set main amplifier mute (I/O: audio-mute)
Force ext audio outputs to ground
Wait until Ambilight has faded out: Output power
Yes
Instruct 200Hz
Tcon to turn off
Switch off LVDS output in 85500
the display
Semi Standby
Figure 5-8 "Active" to "Semi Stand-by" flowchart
Active
Wait 100ms
(I/O: audio reset)
And wait 5ms
switch off Ambilight
Observer should be zero
Switch off POK line
detection algorithm
switch off LCD backlight
(I/O or I²C)
Mute all video outputs
200Hz set?
No
Wait x ms (display file)
Wait x ms
Switch off the display power by
switching LCD-PWR-ON high
back to
div. table
Q551.1E LA
5.
The exact timings to
switch off the
display (LVDS
delay, lamp delay)
are defined in the
display file.
18770_255_100216.eps
EN 25
100216
2010-Jun-25