Summary of Contents for Symbol CRD 1500-4000E

  • Page 2 Symbol reserves the right to make changes to any product to improve reliability, function, or design. Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein.
  • Page 3: Theory Of Operation

    Scout or AVANTGO is required. This software may be purchased from Symbol. Contact your Symbol sales representative for information. About This Guide This guide provides instruction on the setup, use and maintenance of the CRD1500-4000E 4-slot cradle.
  • Page 4 C R D 1 5 0 0 - 4 0 0 0 E Set Up The set up of the cradle includes unpacking, mounting the cradle either on a wall or table top, and connecting the power and serial communication cables. Before setting up the cradle, make sure that SPT 1500 Desktop Software (p/n SW-35138-xx) is installed and running on the host computer, as well as properly configured Network HotSync...
  • Page 5 Q u i c k R e f e r e n c e Connecting Power To connect power to the cradle: 1. Connect the power supply cable round plug to the Power Connector on the back of the cradle, as shown in the follow- ing illustration.
  • Page 6 C R D 1 5 0 0 - 4 0 0 0 E Setting Up for Network Communications The CRD1500-4000E cradle facilitates communication between SPT 1500 terminals and their associated host computers connected to any Ethernet network. As the CRD1500-4000E is an Ethernet device, it must be connected to an Ethernet network which is connected to the same network as the host computers, or an Ethernet network connected to the larger Internet via an...
  • Page 7 Q u i c k R e f e r e n c e If configuration of the unit from the local DHCP server fails, all LED’s flash red. The unit becomes unresponsive until the power is removed, the unit is connected to a network with a DHCP server, and power is restored.
  • Page 8 C R D 1 5 0 0 - 4 0 0 0 E 4. Repeat the previous steps for any additional 4-slot cradles you want to connect. Ethernet Cradle Serial Cradle DC Power Port Expansion DC Power Port (use 9V, 3000ma Port (use 12V, 3000ma Power Supply)
  • Page 9 Q u i c k R e f e r e n c e Wall-Mounting the Cradle The CRD1500-4000E 4-slot cradle can either be seated on a table top or mounted on a wall. Make all cable connections before wall- mounting the cradle.
  • Page 10: Software Configuration

    C R D 1 5 0 0 - 4 0 0 0 E Software Configuration The CRD1500-4000E appears to SPT 1500 terminals inserted into the cradle as a dial-up PPP service. Therefore, just as you would set up a Palm III terminal to connect to an Internet Service Provider (ISP) like Compuserve or Earthlink, the SPT 1500 terminals must be configured for use with the cradle.
  • Page 11 Q u i c k R e f e r e n c e c. Select Modem Sync Prefs. d. Select “Network” and tap “OK”. 2. To configure the LANSync Preferences: a. Select the HotSync application from the main application screen.
  • Page 12 C R D 1 5 0 0 - 4 0 0 0 E 4. To configure the Conduit Setup: a. Select the HotSync application from the main application screen. b. Select the menu icon to display the options menu. c. Select Conduit Setup. d.
  • Page 13 Q u i c k R e f e r e n c e 4. Change the service name to CRD1500-4000E. Leave the user name and password blank. You may enter any phone number you want, except ‘00’, or you may leave it blank. The SPT 1500 terminal will not be able to HotSync if you use ‘00’...
  • Page 14 PC. If the application requires simultaneous connection to a single host database, additional software, available from Symbol, is required. Terminals inserted into daisy-chained cradles are Hotsynced in a round-robin fashion simultaneously with any HotSyncs from local slots.
  • Page 15 Q u i c k R e f e r e n c e Removing the terminal from the cradle while the LED is flashing green will result in a disruption of communication data may be lost. If the terminal is inserted into an inter-connected serial cradle slot while another terminal on the serial cradle chain is communicating with a host, the terminal waits (its LED remains red) until the first terminal finishes communicating.
  • Page 16: Indicator Lights

    C R D 1 5 0 0 - 4 0 0 0 E Indicator Lights Light Indication No terminal is present in the slot. Solid Red Terminal is present, but communication has not started. Green Flashing Terminal is in the cradle, and communicating with the host computer.
  • Page 17: Troubleshooting

    Q u i c k R e f e r e n c e Troubleshooting Symptom Cause Suggested Action LEDs do not light Cradle is not receiv- Make sure the power supply when the cradle is ing power. is securely connected and plugged in.
  • Page 18: Regulatory Information

    1 5 0 0 - 4 0 0 0 E Regulatory Information All Symbol devices are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required. Any changes or modifications to Symbol Technologies equipment, not expressly approved by Symbol Technologies, could void the user’s authority to operate the...
  • Page 19: Warranty

    Q u i c k R e f e r e n c e Warranty (A) Seller’s hardware Products are warranted against defects in workmanship and materials for a period of three (3) months from the date of shipment, provided the Product remains unmodified and is operated under normal and proper conditions.
  • Page 20: Service Information

    +44 118 945 7360 Customer support is available 24 hours a day, 7 days a week. For the latest version of this guide go to: http://www.symbol.com/manuals. 72-52665-01 Revision A— September 2002 Symbol Technologies, Inc. One Symbol Plaza, Holtsville, N.Y. 11742-1300...