Advertisement

ECM Specifications
Model Number *
CFM from .1 - .6" W/C
A/C Tonnage Selection
A/C
Cooling
CFMs
(100 cfm
2 ton
800
steps
available
2.5 ton
1000
for A/C)
3 ton
1200
3.5 ton
1400
Air Temperature Rise Selection
57° Rise
Heating
(at approx.
63° Rise
rated input
69° Rise
BTU)
75° Rise
83° Rise
The standard motor size may not support this cfm at high static pressures.
* Model numbers end with 'E' to signify ECM motor.
Additional Features
General
• Eliminates the need for air temp thermostat to control fan cycling by using time instead.
• Selectable blower turn-on and turn-off delays to adjust comfort & efficiency
(turn-on: 30, 60, 120 & 240 sec; turn off: 2, 4, 6 & 8 min)
• Three blower operating choices: HEAT, COOL & FAN for best efficiency for each mode.
• Reduces A/C blower speed 50% on demand to increase dehumidification.
• Cooling blower delays of 10 seconds on, and 45 seconds off to enhance cooling comfort and efficiency.
Cycle Control
• 4 minute minimum A/C off time to reduce Short-Cycle related failures.
• A high limit will cause the blower run at the selected HEAT speed. It will then run for the HEAT turn off
time afterwards in the absence of a HEAT call.
• Blower operation will "time out" before mode is switched between HEAT & COOL to prevent stress related
evaporator failures.
• Burner Cut-Off on high limit
Speed Control
• Selectable air temperature (heat) rise from Return to Supply Plenum (choose from: 63, 69, 75 and 85 º F)
• Selectable CFM rates for matching A/C tonnages. These CFM selections support from 2.0 to 3.5 tons.
• Maximum CFM's are limited by the maximum RPM of the ECM motor and the duct static pressure.
Please refer to the manual addendum for guidelines.
Diagnostics
• Control Input LED's indicate active thermostat input lines.
• Diagnostic LED indicate:
1. Active Operation (turn full on during burner or compressor operation)
2. A HIGH LIMIT condition. (flash on/off at 2 ½ times per second)
OL5-85...E
OL11-105...E
Continuous
A/C
Fan
CFMs
500
800
500
1000
600
1200
700
1400
Heating CFM
Heating CFM
1400
1260
1162
1050
938
OH5-85...E
Continuous
A/C
Continuous
Fan
CFMs
500
800
500
1000
600
1200
700
1400
Heating CFM
1400
1500
1260
1350
1162
1245
1050
1125
938
OH11-105...E
A/C
Continuous
Fan
CFMs
Fan
500
800
500
500
1000
500
600
1200
600
700
1400
700
Heating CFM
1500
1350
1245
1125
Form No. PL81410021002 - 6/05 - 20Ms