Viessmann VITODENS 100-W Installation And Service Instructions Manual page 38

For contractors. wall mounted gas condensing boiler natural gas and lpg version
Hide thumbs Also See for VITODENS 100-W:
Table of Contents

Advertisement

Troubleshooting
Fault messages on the display
Displayed
System characteris-
fault code
tics
51
No DHW heating
52
Burner blocked
58
No DHW heating
59
No DHW heating
5A
Burner blocked
A9
Control mode without
Open Therm device
b0
Burner blocked
b8
Burner blocked
E3
Burner in a fault
state
E5
Burner blocked
F0
Burner blocked
F1
Burner in a fault
state
38
(cont.)
Cause
Short circuit, outlet
temperature sen-
sor
Short circuit, flow
sensor
Lead break, cylin-
der temperature
sensor
Lead break, outlet
temperature sen-
sor
Lead break, flow
sensor
Communication
fault Open Therm
device
Short circuit, flue
gas temperature
sensor
Lead break, flue
gas temperature
sensor
Fault in safety
chain
Internal fault
Internal fault
Max. flue gas tem-
perature exceeded
Measures
Check the sensor (see
page 47).
Check connections and
lead; replace sensor if
required.
Check the sensor (see
page 44).
Check the sensor (see
page 47).
Check connections and
lead; replace sensor if
required.
Check connections and
lead; replace Open Therm
device if required.
Check the sensor (see
page 48).
Check the sensor (see
page 48).
Check the temperature
limiter and connecting
leads (see page 45).
Check the control unit,
and replace if required.
Check the ionisation elec-
trode and cables.
Press "Reset" (see
page 40).
Replace control unit.
Check heating system fill
level. Check circulation
pump. Vent the system.
Press "Reset" (see
page 40).