3Com SuperStack II Hub 10 User Manual
3Com SuperStack II Hub 10 User Manual

3Com SuperStack II Hub 10 User Manual

3com switch/hub technical information
Hide thumbs Also See for SuperStack II Hub 10:

Advertisement

T
ECHNICAL
Related Standards
The Hub 10 Telco has been designed to conform to the following
standards:
Functional
ISO 8802/3, IEEE 802.3
Safety
UL 1950, EN 60950, CSA 22.2 #950
EMC
EN 55022 Class B, EN 50082-1, FCC Part 15 Class A,
CSA C108.8 Class A
(screened cables must be used to ensure
compliance with these standards)
Environmental
EN 60068 (IEC 68)
Physical
Width
440mm (17.3 ins)
Depth
224mm (8.8 ins)
Height
44mm (1.7 ins) or 1U
Weight
2.6kg (5.7lb)
Mounting
free standing,
or 19" rack or wall mounted using kit supplied
SuperStack™ II Hub 10
Telco (3C16672A)

User Guide

I
NFORMATION
DUA1667-2AAA03
Electrical
Hub 10 Telco only
Power Inlet
Fuse Protection
Power Consumption
Power Dissipation
Hub 10 Telco & Management Module
Power Inlet
Fuse Protection
Power Consumption
Power Dissipation
Environmental
Operating Temperature
Humidity
IEC 320
2 Amps
22 VA
73 BTU/hr
IEC 320
2 Amps
30 VA
100 BTU/hr
0-50°C (32-122°F)
0-90% (non-condensing)

Advertisement

Table of Contents
loading

Summary of Contents for 3Com SuperStack II Hub 10

  • Page 1: User Guide

    SuperStack™ II Hub 10 Telco (3C16672A) User Guide ECHNICAL Related Standards The Hub 10 Telco has been designed to conform to the following standards: Functional ISO 8802/3, IEEE 802.3 Safety UL 1950, EN 60950, CSA 22.2 #950 EN 55022 Class B, EN 50082-1, FCC Part 15 Class A, CSA C108.8 Class A (screened cables must be used to ensure compliance with these standards)
  • Page 2: S Afety I Nformation

    AFETY Please read the following safety information carefully before installing the Hub 10 Telco. WARNING: Installation and removal of the unit must be carried out by qualified personnel only . Connect the unit to an earthed power supply to ensure compliance with safety standards.
  • Page 3 This is only necessary on units which have ports assigned as standby. Standby ports in resilient link pairs can only be configured on SuperStack II Hub 10 or LinkBuilder FMS II units. “ Products and Bulletin Security features are described in the manual which comes with your Hub 10 Management Module.
  • Page 4: Front Panel

    To form an inter-repeater link using two Hub 10 Telcos, connect port 24 on unit 1 to any port on unit 2. Ensure that the MDI switch on unit 1 is IN (MDI) and that if port 24 is used on unit 2, the MDI switch is OUT (MDIX).
  • Page 5: Rear Panel Connection

    Redundant Power System. Management Module or Advanced RMON Module Slot The Hub 10 Telco can be fitted with an optional SuperStack II Hub 10 Management Module or Advanced RMON Module. When the module has an IP/IPX address, you can then use SNMP management to manage the stack containing the unit.
  • Page 6: Stacking Units

    11 or 12 . Connect the plug to the power supply outlet socket and switch on the power supply at the socket. If you are using a 3Com Redundant Power Supply make sure it is switched on.
  • Page 7: Bulletin Boards

    RODUCTS AND Products SuperStack II Hub 10 is part of the SuperStack II range of 3Com products. Contact your supplier for the latest product information. Hub 10 hubs 3C16670A SuperStack II Hub 10 12Port TP 3C16671A SuperStack II Hub 10 24Port TP...
  • Page 8: Warranty

    Material Authorization (RMA) number marked on the outside of the package, and sent prepaid, insured, and packaged appropriately for safe shipment. The repaired or replaced item will be shipped to Customer, at 3Com's expense, not later than thirty (30) days after receipt of the defective product by 3Com.

This manual is also suitable for:

Superstack ii 103c16672a

Table of Contents