Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operating and safety instructions.
·
All information in these instructions is based upon the
latest product information available at the time of
publication. Kohler China reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
·
These instructions contain important care, cleaning, and
warranty information -
please leave instructions for the
consumer
.
ORDERING INFORMATION
REACH One-piece Toilet
.........................................K-3856T-S
Includes
REACH Quiet-Close
(Hidden Hinge Base)
REACH One-piece Toilet
.........................................K-3856T-B
Includes
REACH
Toilet Seat
(Hidden Hinge Base)
NOTES
·
Observe all local plumbing and building codes.
·
Shut off the water supply.
·
Seat post holes are on 140mm (5-1/2") centers.
·
Ensure that the new drain has the correct roughing-in
dimension. This toilet has a 305mm (12") roughing-in
dimension.
See Roughing-in
·
Closet flange must be 305mm (12") on-center from wall.
·
Carefully inspect the new fixture for any sign of damage.
·
For new construction, refer to the dimensions in
installation step
for locating the shut-off valve.
·
Fixture dimensions are nominal and conform to tolerances
established by ASME Standards (A112.19.2-2008).
WARNING: Risk of personal injury or product
damage
: Handle vitreous china products very carefully.
Vitreous china can break and chip if you overtighten
bolts and nuts.
WARNING: Risk of external leakage
nut has been factory-tightened to design specifications.
If re-tightening is required, wrench tighten one turn
past finger tight .
1182020-T01-A
Toilet Seat
..................................K-4087T
..................................K-4088T
.
. The fill valve
VITREOUS CHINA ONE-PIECE TOILET
·
·
·
.......................................................K-3856T-S
(
)
.............................................................K-4087T
........................................................K-3856T-B
(
)
.............................................................K-4088T
·
·
·
140mm
·
)
·
·
·
·
2008)
528137
-1-
REACH
INSTALLATION INSTRUCTIONS
K-3856T-S/K-3856T-B
305mm(
305mm
ASME
Copyright Kohler China Ltd., 2011
-
(A112.19.2-
, 2011

Advertisement

loading

Summary of Contents for Kohler REACH K-3856T-S

  • Page 1 · · All information in these instructions is based upon the latest product information available at the time of publication. Kohler China reserves the right to make changes in product characteristics, packaging, or availability at any time without notice. ·...
  • Page 2: Tools And Materials Required

    If you use a rigid connection, take care not to apply side forces to the bottom of the fill valve. Unit: mm Reference Value Finished Wall Supply Kohler reserves the right to change marked dimensions without prior notice. 1182020-T01-A...
  • Page 3: Installation

    The expansion of cement due Closet to a rise in temperature may make the toilet crack or cause Flange damage. Kohler is not responsible for any damage caused by installation with the use of cement. 1182020-T01-A...
  • Page 4 To install supply shut-off valve Supply Shut-Off Valve Install toilet supply shut-off valve so it is 140mm above floorline and 135mm to the left of the centerline of the closet flange. Centerline of supply shut-off outlet should extend 102mm from finished wall. Install the supply shut- off valve with outlet vertcial.
  • Page 5 Cut excess. Fix bolt cap. 6 mm 6 mm Cut excess. Connect supply and turn on the water. Flush several times and check for leaks. 10mm Supply Alimentation 10mm Fill Float With Ballast Test flush the toilet. Periodically check all connections for leaks for several days following installation.
  • Page 6 To lower water level: Move water cup down to a proper Screw height and rotate screw anticlockwise to achieve the desired water level. (Refer to float adjustment instructions.) To elevate water level: Rotate screw clockwise and raise float to the desired water level. Elevate water cup to a proper position as well.
  • Page 7 A. Partially close the water supply shut-off valve if the water pressure to the toilet is too tank is filling. high. Check the toilet performance following any such adjustment. B. Remove dirt or obstructions from the valve head. Flush the lines. IMPORTANT: Use only genuine Kohler parts as shown to avoid property damage. 1182020-T01-A...
  • Page 8: Consumer Responsibilities

    CAUTION: Don t use any cement while installing the toilet. Heat expansion of the toilet may damage the feet of the toilet. Kohler will not be responsible for any damage because of using cement. WARNING: Risk of product damage. Do not throw into the toilet what is easy to block it, such as newspaper, paper pilch, sanitary towel.