Error Codes - Mitsubishi Electric LT-40133 Service Manual

Lcd, vlp38/vlp38+/vlp38++ chassis
Hide thumbs Also See for LT-40133:
Table of Contents

Advertisement

MODELS: LT-40133 / LT-46133 / LT-52133 / LT-40134 / LT-46144 / LT-52144 / LT-46244 / LT-52244
3. Error Code Operational Check
Note: The TV must be in "Shut Down" and not have been switched Off, to perform the Error Code Opera-
tional Check. When the TV is switched Off, the code automatically resets to "12" No Error.
Pressing the front panel "INPUT" and "MENU" buttons at the same time, and holding for 5 seconds,
activates the Error Code Mode. The "POWER LED" flashes denoting a two digit Error Code, or indicating no
problem has occurred since the last Initialization.
Note: The front panel buttons must be used, NOT those on the Remote Control.
The number of flashes indicates the value of the MSD (tens digit) of the Error Code.
The flashing then pauses for approximately 1/2 second.
The LED then flashes indicating the value of the LSD (ones digit) of the Error Code.
The Error Code is repeated a total of 5 times.
(EXAMPLE) - When the error code is 35, the LED flashes as follows

ERROR CODES

Error Code
12
No error since last power On
27
Inverter short detected (IC7A01 pin 116 = High when short)
28
FPGA download failure (IC7A01 pin 44 = Low when short)
29
FRC communication error (VLP38+/VLP38++) - (3.3V-SDA&SCL)
35
DM Fan stopped (VLP38++ only)
44
Disconnected LVDSI cable between DM and LCD module
47
DM temperature too high
48
LCD Panel short detected (IC7A01 pin 124 = Low when short)
58
Signal Short Detected (IC7A01 pin 89 = Low when short)
59
DM short detected ( (IC7A01 pin 125 = Low when short)
All manuals and user guides at all-guides.com
Description
Page 20
Connector
PB-PD-PF
VR
JD
VR-CN1
PB-PG

Hide quick links: