Operation; Cleaning And Maintenance; Troubleshooting - Broan LP50100DC Installation Manual

Loprofile dc ventilation fan
Hide thumbs Also See for LP50100DC:
Table of Contents

Advertisement

Available languages

Available languages

Page 7

Operation

To Operate Fan
Use an ON/OFF switch to operate this ventilator.
Do not use a speed control.
Speed Selection Switch
WARNING
Before servicing or cleaning unit,
switch power off at service panel and lock the service
disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
Select 50, 80 or 100 CFM
based on your room size
and desired air flow.
50 80 100

Cleaning and Maintenance

To Clean
For quiet and efficient operation, long life and attractive
appearance, remove Grille and vacuum interior of unit with
a dusting brush attachment.
The Motor is permanently lubricated and never needs
oiling. If the motor bearings are making excessive or
unusual noises, replace the Blower Assembly.

Troubleshooting

Symptom: The fan does not run.
• Check for an open fuse or circuit breaker in the building's
service panel.
• Check that the plug-in connections for the Motor Control,
Motor, and Speed Selection Switch are seated firmly in
place.
• Check that the Blower Wheel spins freely.
Symptom: The fan runs erratically.
• Check that the Blower Wheel is firmly attached to the
Motor shaft and both spin freely.
Symptom: The fan seems noisy.
• Check that the back draft damper in the fan's Duct
Connector pivots freely. Screws used to attach the
ducting to the Duct Connector may be preventing the
damper from opening.
• Check that the back draft damper in the wall or roof cap
pivots freely. These dampers are sometimes mistakenly
painted shut or obstructed by bird and insect debris.
LP50100DC
Installation Guide
n

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents