2.4

Designation of the butterfly valve

The designation of the butterfly valve includes the following details:
Details
Manufacturer
Valve type
Body material
Size
Maximum pressure
Perm. temperature
Perm. pressure
Serial no.
2009 onwards
Serial no.
up to 2008
Year of manufacture
Conformity
Identification no.
Direction of flow
Table 1 – Designation of the butterfly valve
Keep the labeling on the valve body and on the nameplate to ensure that the valve can be identified at all times.
3.

Transport and storage

Butterfly valves must be carefully handled, transported and stored:
Store the valve with its protective packing and/or with its protective caps in place in the end connections. Store and
transport the butterfly valves that weigh over approx. 10 kg on pallets (or a similar type of support) right up to the point of
installation. The packing is designed to protect the valve's internal parts against being damaged.
Store the valve in a closed room before it is installed. Protect it against damaging influences such as dirt or moisture.
Make sure, in particular, that the facings of the flanges are not damaged through mechanical or other influences. Do not
stack butterfly valves!
As a rule, butterfly valves are delivered in the closed position. Store the valves in the condition they were delivered in. Do
not operate the valve.
4.

Installation in the pipeline

4.1

General

The same instructions apply for installing the butterfly valves in the pipeline as for connecting pipes and similar pipeline
equipment. The following instructions additionally apply for butterfly valves. Also observe section 3 for transporting the butterfly
valve to the point of installation.
5 of 9
Specifications subject without notice
Edition: August 2017
Designation
Comments
Pfeiffer
Address see section 8 <Information>
BR (and number)
e.g. BR 14a = Series 14a, see Pfeiffer catalogue
e.g.: 1.4408
Material number acc. to DIN EN 10213-4
DN (and number)
Value in mm, e.g. DN200
PN (and number)
Value in bar at room temperature
TS (and number)
PS and TS are associated values at maximum permissible operating
temperature and maximum permissible operating pressure.
PS (and number)
e.g.: 211234/001/001
207
e.g.: 2070153/001/001
On request of customer the year of manufacture is stamped on the
e.g.: 2017
valve.
CE
Conformity is certified separately by the manufacturer
0035
Notified body as per EU Directive = TÜV Anlagentechnik GmbH
Note: see note in section 4.2 <Installation instructions>
27
1234
/001
/001
0153
/001
/001
Valve No. into the Item
Item in Commission
Commission
year of manufacture (e.g. 27=2017)
Valve No. into the Item
Item in Commission
Commission
year of manufacture (e.g. 207=2007)