Robin America RGX180 Service Manual page 34

Robin generator service manual
Table of Contents

Advertisement

8-2
AC OUTPUT
MEASURING
;a
LOA;
TOACd/LE+@
$))
Use a circuit like the one shown in Fig. 8-7 for measuring XC output. A hot plate or lamp Lvith a power factor of 1 .O ma>-
be used as a load. Adjust the load and rpm. and check that the voltage range 1s as
specified
in Table
5-1 at the rated
amperage
and rated rpm
I
Rated voltage
1lOV
120v
220v
230V
'
240V
I
Voltage
range
108 - 115V
118 - 125V
218 - 225V
228 - 235V
238 - 245V
I
Table 8- 1
8-3
DC OUTPUT
MEASURING
Fig. 8-8
Switch the powr on. Khen 1.45R resistance is attached as a load. check that the voltage is within the 13 to 1 IL7 range.
NOTE:
If a battery
is connected
as the load, the output
voltage increases by about
7 TO ZV, possibly
causing battery
over-
charge.
Control
battery
liquid
level during
charging
to prevent
overcharging.
8-4
MEASURING
INSULATION
RESISTANCE
Connect a meger tester to one of the two receptacle output
terminals and the ground terminal. then measure rhe insula-
tion rssistanx.
An insulation resistance of 1 megohms or
more is nxmal.
(The original insulation resistance at the
time oishlpment from tht factor! is 10 megohms or more.)
Ji it is I?ss than 1 mqohm. disassembl? the generatnr and
measure the insulation resistance of the statOr. rotor and
cant;01 bc!x indi\!dual!~-.
I
I
I
1
. .
Fig. 8-9
-32-