9-4-16
HEAD COVER AND BLOWER HOUSING
(1)
Set the head cover with the M6 x 8 flange bolts (at two places in the generator side).
(2)
Set the blower housing to the crankcase with M6 x 12 bolts.
Note: The two M6 x 12 flange bolts for clamping the blower housing and head cover are used
when the fuel tank is installed.
Blower Housing
M6x8 Flange Bolt
Head Cover
(2
PCs.1
I
2 Flange Bolt (2
Clamped with
the fuel tank
PCs.1
M6x12 Flange Bolt (2
PCS.)
Fjg. 94-78
9-4-1'7 RECOIL STARTOR
Set the recoil startor with four M6 x 8 flange bolts.
Note: Don't use bolts which are longer than 8mm. If used, they might run against fans of the
flywheel.
v
M6x8 Flange Bolt (4
PCS.)
Recoil Starter
Fig. 94 79