Robin America PKX Series Robin Pump 201 Instructions For Use Manual

Subaru robin pkx series robin pump product manual

Advertisement

PKX
201/301/401
201ST/301ST
9ZZ9990035
北米
series
201H
201T/301T

Advertisement

Table of Contents
loading

Summary of Contents for Robin America PKX Series Robin Pump 201

  • Page 1 series 201/301/401 201ST/301ST 9ZZ9990035 北米 201H 201T/301T...
  • Page 2 PKX201,301,401, 201H, 201ST, 301ST Single grade Multi grade Ambient temperature PKX201T, 301T 10W-30 10W-40 40 C 104 F PKX201T, 301T 0.6 - 0.7 mm PKX201,301,401, 201H 201ST, 301ST...
  • Page 3: Table Of Contents

    Thank you very much for purchasing a ROBIN PUMP. This manual covers operation and maintenance of ROBIN PUMP. All information in this publication is based on the latest product information available at the time of approval for printing. Please read this manual carefully before operating. Please take a moment to familiarize yourself with the proper operation and maintenance procedures in order to maximize the safe and efficient use of this product.
  • Page 4: Safety Precautions

    1. SAFETY PRECAUTIONS Please make sure you review each precaution carefully. Pay special attention to statement preceded by the following words. WARNING “WARNING” indicates a strong possibility of severe personal injury or loss of life if instructions are not followed. CAUTION “CAUTION”...
  • Page 5 Do not touch the spark plug and ignition cable when starting and operating the engine. ■ Operate the pump on a stable, level surface. ■ If the engine is tilted, fuel spillage may result. NOTE Operating the pump at a steep incline may cause seizure due to improper lubrication even with a maximum oil level.
  • Page 6 SYMBOLS Read the owner's manual. Stay clear of the hot surface. Exhaust gas is poisonous. Do not operate in an unventilated area. Stop the engine before refueling. Fire, open flame and smoking prohibited. On (Run) Off (Stop) Engine oil Add oil Plus ;...
  • Page 7: Components

    2. COMPONENTS (See Fig. 1 1 1 1 1 ) NOTE Please refer to the illustrations on the back page of the front cover or back cover for Fig. 1 1 1 1 1 to i i i i i indicated in the sentence. CENTRIFUGAL PUMP (PKX201,301,401,201H) SEMI TRASH PUMP (PKX201ST,301ST) (See Fig.
  • Page 8: Pre-Operation For Starting

    3. PRE-OPERATION FOR STARTING (See Fig. 2 2 2 2 2 ) 1. CONNECT SUCTION HOSE (See Fig. 2 2 2 2 2 -q q q q q ) Use a reinforced-wall or wire braided hose to prevent suction collapse. Since the pump self-priming time is directly proportional to hose length, a short hose is recommended.
  • Page 9: Operating Your Pump

    4. OPERATING YOUR PUMP 1. STARTING (See Fig. 3 3 3 3 3 ) (1) Open the fuel cock. (See Fig.3-q) (2) Turn the STOP SWITCH to the position “ (See Fig.3-w) (3) Set the speed control lever 1/3 of the way towards the high speed position.
  • Page 10 2. PERIODIC INSPECTION Periodic maintenance is vital to the safe and efficient operation of your pump. Check the table below for periodic maintenance intervals. IT IS ALSO NECESSARY FOR THE USER OF THIS PUMP TO CONDUCT THE MAINTENANCE AND ADJUSTMENTS ON THE EMISSION-RELATED PARTS LISTED BELOW TO KEEP THE EMISSION CONTROL SYSTEM EFFECTIVE.
  • Page 11 3. INSPECTING THE SPARK PLUG (See Fig.7 7 7 7 7 -q q q q q ) (1) Clean off carbon deposits on the spark plug electrode using a plug cleaner or wire brush. (2) Check electrode gap. The gap should be 0.6 mm to 0.7 mm.
  • Page 12: Preparations For Storage

    6. PREPARATIONS FOR STORAGE 1. WATER (See Fig.8 8 8 8 8 -q q q q q ) Drain all water from the drain plug. CAUTION When retightening drain plug, be sure to clean the drain plug and the thread of casing. Otherwise, the thread may be damaged.
  • Page 13: Easy Troubleshooting

    9. EASY TROUBLESHOOTING 1. PUMP DOES NOT RUN . Engine dose not start. ■ (See 9.-4 “4. WHEN ENGINE DOES NOT START Sticking of impeller ■ (Disassemble and clean.) 2. PUMPING VOLUME IS SMALL. Sucking air at suction side. ■ (Check piping at suction side.) Drop off engine output ■...
  • Page 14: Specifications

    10. SPECIFICATIONS MODEL PKX201 Type Suction x Delivery 50 x 50 (2 x 2) Diameters mm(in.) Total Head m(ft) 30 (98) Maximum Delivery Volume 600 (158) Liter(U.S.gal) / min Suction Head m(ft) 8 (26) Axle Seal Material (Mechanical Seal) Model EX13 Type Lublicant...
  • Page 15 ISSUE EMD-PU2117 PRINTED IN JAPAN May 2005 CE-SK...

Table of Contents