Compatibility Notes
This kit must be installed in conjunction with a DaVinci pre-configured for heat-exchanger use.
NOTE: Does not work for island or bay configurations or any unit with 58' tall glass.
Packing List
Blower Assembly with Strain Relief
Blower Grill
Heat Exchanger Lead (2 wire molex)
(4) Hose Clamps and (4) Lock-Ties
Register Boot (4" Dia. to 2.25" x 10") (102mm Dia. to 58mm x 254mm)
Output Register (2.25" x 10") (58mm x 254mm)
25' (7.5M) 4" (102mm) Diameter Insulated Duct (U.L. 181)
Category 2 Heat Exchanger Location
For category 2 fireplaces, the heat exchanger is always located on the primary module (near the
exhaust).
Heat Exchanger Length (Inside Fireplace)
Category 1:
3 Burner = 3' Heat Exchanger (1M)
4 Burner = 4' Heat Exchanger (1.25M)
5 Burner = 5' Heat Exchanger (1.5M)
Category 2:
6 Burner = 5' Heat Exchanger (1.5M)
7 Burner* = 4' Heat Exchanger (1.25M) (4 burner + 3 burner modules)
* For 7 burner units that are shipped pre-assembled, the heat exchanger will need to be installed.
Follow the instructions on the last page of this document for installation instructions.
8 Burner = 4' Heat Exchanger (1.25M) (two (2) 4 burner modules)
9 Burner = 5' Heat Exchanger (1.5M) (5 burner + 4 burner modules)
10 Burner = 5' Heat Exchanger (1.5M) (two (2) 5 burner modules)
Additional Options
Remote Intake Grill, SKU # 94400131 (allows for intake box to be concealed & air to be drawn from a
register)
Installation Warnings
Warning:
This kit must be installed as specified in these instructions. Do not modify any component.
Warning:
Use of any external blower other than the Travis Power Heat Duct Blower will void the warranty
and listing of this appliance and may create a fire hazard.
Warning:
Disconnect power to the fireplace (turn the service breaker off) before conducting the installation.
Enable power to the fireplace only after the installation is verified.
Note:
This kit must be installed by a qualified service technician.
Note:
Some building codes may require the use of firestop spacers whenever the duct passes from
room to room.
Page 1 of 10
DaVinci Heat Exchanger
Touch-Screen Version
17601915 - 12/20/17
Travis Industries, Inc.

Advertisement

loading

Summary of Contents for Travis Industries DaVinci

  • Page 1 DaVinci Heat Exchanger Touch-Screen Version Compatibility Notes This kit must be installed in conjunction with a DaVinci pre-configured for heat-exchanger use. NOTE: Does not work for island or bay configurations or any unit with 58’ tall glass. Packing List ...
  • Page 2: Installation Overview

    DaVinci Heat Exchanger Touch-Screen Version Installation Overview The overview below details installation concerns for the type of heater being used. Install the heat duct prior to installing drywall. The homeowner must turn the blower on and off manually. The blower will remain on until the fireplace is turned off.
  • Page 3 DaVinci Heat Exchanger Touch-Screen Version Fireplace Heat Exchanger Location MIN. 1" (25mm) CLEARANCE REQUIRED TO HEAT EXCHANGER BOX This clearance is to top, sides, and bottom of the box. The duct has a 0" clearance. 4.75" 121mm 5.75" 9.5" 147mm 242mm 15"...
  • Page 4 DaVinci Heat Exchanger Touch-Screen Version Re-Routing the Heat Exchanger Inlet(s) Upwards  The inlets are shipped in the downward positon. One or both inlets may be re-routed upwards.  Remove the 4 screws holding the cover plate and gasket in place.
  • Page 5: Duct Installation

    DaVinci Heat Exchanger Touch-Screen Version Duct Installation Maximum Duct Length  Maximum duct length is 50’ (15M) (inlet and outlet combined length). Duct Routing  Duct has a 0” clearance to combustibles.  Do not route duct next to any surfaces that reach 170° F. (76° C.) or greater (must maintain a minimum 1”...
  • Page 6 DaVinci Heat Exchanger Touch-Screen Version Duct Installation  Attach insulated duct to the connections using the included hose clamps for the inner liner and lock-ties for the outer layer.  The flexible duct must be supported every 24” (610mm) to 36” (915mm) on horizontal sections.
  • Page 7 DaVinci Heat Exchanger Touch-Screen Version Blower Box Placement  The blower box has a removable grill that allows access to the blower. The blower box must be placed so it may be accessed at a later time.  The blower box may be placed upright (power inlet on the top) or with the grill facing upwards or downwards.
  • Page 8: Wiring Instructions

    DaVinci Heat Exchanger Touch-Screen Version Wiring Instructions WARNING: All wiring should be done by a qualified electrician and shall be in compliance with local codes and with the current National Electric Code ANSI/NFPA 70 (in the U.S.), or with the current CSC22.1 Canadian Electric Code (in Canada).
  • Page 9: Maintenance Instructions

    DaVinci Heat Exchanger Touch-Screen Version Wiring on the Fireplace Junction Box  See manual for details on accessing the junction box.  Route the power from the heat exchanger blower to the connector on the fireplace as shown below. NOTE: The ground wire from the blower should be connected to the ground wire from the power in.
  • Page 10 DaVinci Heat Exchanger Touch-Screen Version Heat Exchanger Installation on 7 Burner Units  For 7 burner units that are shipped pre-assembled, the heat exchanger will need to be installed. Follow the instructions below for installation. 1. Use a 5/16” nut driver to remove the (10) screws indicated below (set aside for reinstallation). Only remove the screws indicated with the black circles.