Siemens SIMATIC Series Getting Started page 14

Industrial pc
Hide thumbs Also See for SIMATIC Series:
Table of Contents

Advertisement

Description
2.4 Status displays
Front status displays
PN Ι MPI/DP
(optional)
WATCHDOG
TEMP
FAN
HDD1 ALARM
HDD2 ALARM
HDD3 ALARM
All displays are lit
*
14
Display of the
communication status
to S7 or PROFIBUS
Status display for
CP 1616 onboard
WATCHDOG status
display
Internal temperature
monitoring
Fan status (only with
active DiagBase or
DiagMonitor software)
Hard disk alarm in
conjunction with RAID
and monitoring
software
Error in early BIOS
Post
For unique labeling, the LAN interfaces are numbered on the enclosure. The numbering by the
operating system may deviate from this.
No connection
OFF
No data traffic
PROFIBUS not equipped
MPI/DP data traffic
GREEN
No connection
OFF
No data traffic
CP 1616 onboard not
equipped
CP disabled
No error, communication
established
Charging in progress
CP 1616 driver not installed
CP in NDIS mode
Link status error
Flashes slowly
RED
IO controller: IO device cannot
be addressed
IO controller: Duplicate IP
address
Flashes rapidly
Exception error: diagnostics via
RED
Web or SNMP is no longer
possible
Diagnostics information
RED
available
No communication established
OFF
WATCHDOG not activated
GREEN
WATCHDOG monitoring enabled
RED
Monitoring time elapsed
OFF
Internal temperature OK
RED
Internal temperature critical
OFF
Fan speed OK
RED
Fan speed too low
OFF
RAID is OK
One RED
HDD1, HDD2 or HDD3 not OK
All RED
RAID not OK
(for information on locating the
faulty HDD, refer to the RAID
system section)
All flashing
RAID is synchronized
All lit
CPU startup failure
Error in early POST
Getting Started, 12/2010, A5E02669190-02
SIMATIC IPC847C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic ipc847c