Finishing Your Fireplace; Ash Disposal - Vanguard Aristocrat V42E Installation Instructions Manual

Table of Contents

Advertisement

MANTEL
A mantel may be installed if desired. See Figures 21 or 22 for
minimum heights above and beyond opening of fireplace face.
Woodwork, such as wood trim and mantels, and other combustible
material, shall not be placed within 6 inches of a fireplace opening.
Combustible material above and projecting more than 1
a fireplace opening shall not be placed less than 12 inches from the top
of the fireplace opening. NFPA Standard 211 sections 7-3.3.3.
1
12
/
" REF
4
6"
REF
33 DEG
3"
MINIMUM 12"
NOM
1
6" MINIMUM
MAX
TOP OF
LOUVERED
OPENING
12
1
/
"
4
REF
f i r e - p a r t s . c o m
6"
REF
33°
3"
NOM
WITHIN 12"
1
MAX
6" MIN
Figure 21
1
3
/
"
8
MAX.
2
/
1
"
8
MIN.
Figure 22
1
/
inches from
2
COMBUSTIBLE
MATERIAL
SAFE ZONE FOR
PROJECTION OF
COMBUSTIBLE
MATERIALS
NOTE: DRAWING NOT
TO SCALE
1
/
"
2
UPPER
SECTION OF
FIREPLACE
COMBUSTIBLE
MATERIAL
SAFE ZONE FOR
PROJECTION OF
COMBUSTIBLE
MATERIAL
1
/
"
2
UPPER
SECTION OF
FIREPLACE
TOP VIEW
OUTER SURROUND
COMBUSTIBLE
MATERIALS
SAFE
ZONE
33°
24" MIN. TO
ADJACENT WALL

FINISHING YOUR FIREPLACE

Wall board (Gypsum board, sheet rock, drywall, etc.) may make
direct contact with the sides and the top of the fireplace face. It is
important that combustible materials do not overlap the face itself.
Brick, glass, tile or other noncombustible materials may overlap the
front face provided they do not obstruct essential openings like
louvered slots or any other openings. When overlapping with noncom-
bustible facing material, use only noncombustible mortar or adhesive.
CAUTION: DO NOT COVER UP THE TOP OR BOTTOM
FACE LOUVERS.

ASH DISPOSAL

Ashes should be placed in a metal container with a tight-fitting lid.
The closed container of ashes should be placed on a noncombustible
floor or on the ground, well away from all combustible materials,
pending final disposal. If the ashes are disposed of by burial in soil
or otherwise locally dispersed, they should be retained in the closed
container until all cinders have thoroughly cooled.
WARNING: Risk of fire; Replace grate only with DESA
International Model 42E GR grate only.
FUEL: Use wood or if a vent-free or decorative gas appliance
is installed, burn propane/LP or natural gas only.
8
55510

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aristocrat v42ec2

Table of Contents