Di mension S h eet
29-170C
Page 4
Westinghouse AB DE-ION® Cu rrent Li miting Circuit Breakers
Type LCL Current limiting Breakers, Drilling Plans
For Plug-In Blocks
.500 ( 1 2.701 Dia
1.125
{28.56)
(6) Holes for .375 (9.521
Mounting Bolts
1 1
I I
{242
791
1 I
� - �� - - '
I
1
14.750
, 1 , I 1
I I ,
- (lHandle -
I
]]_
5.188
_
1 .094 R
(27.77) R
Terminal Arrangements
Cable
Catalog
Ampere
Wire
Size
Number
Rating
For Use With Cu/AI Cable (Supplied as Standard)
Single
TA225LA1
125-225
#6-350 MCM Cu or
#4-350 MCM AI
Double
TA400LA1
250-400
#4-250 MCM Cu/AI Plus
3/0-600 MCM Cu/AI
For Use Wi t h Copper Cable Onl y (Must be Specified)
Single
TA225LA
125-500
#6-350 MCM
Double
#4-250 MCM and
TA400LA
250-400
3/0-600 MCM
&
Cutler-Hammer
West i n g house
Cutler-Ha m m e r Products
Five Pa rkway Center
Pittsburgh, Pennsylva n i a , U . S .A. 1 5220
For Rear Connected Studs
+ - � -
(For Non-Conductive Panels)
'
1 I
I
I
1
I
- �
I
'1
1;
g�
1
i
;
_
_
-+ I ____j 1
a
1
5.500
{139.651
Rear Connected Studs
Stud Ampere
Stud Style
Rating
Number
125-225
1241345
125-225
1241392
125-225
1241346
0587383G15 .750 119.041 . 16 1406.24)
250-400
250-400
05B7383G16 .750 (19.041 - 16 1406.241
250-400
0587383G17 .750 119.041 - 16 {406.241
Do Not Use More Than 25 Ft.
Lbs. Torque to Tighten Nuts
For Mounting Bolts
I
.563 1 1 4.281 Dia. Hole
I
for 1 25 to 255 Amps
9.563
{242.791
-
813(20 631 D1a. Hole
for 250 to 400 Amps
14 750
1 6 Holes for
1374 501
' 3 Pole Breaker
4 Holes for
2-Pole Breaker
Om1t 2 Center Holes
'._
; fo r 2-Pole Breaker
1.375
134.911
Thread
Dimension
Size
A
.500 {12.701 - 13 {330.071
3.188 {80.931
.500 112.701 - 13 {330.071
4.938 1125.361
.500 {12.701 - 13 1330.071
6.250 1158 . 691
5.469 1138.85)
7.969 (202.331
10.469 (265.80)
Front Cover Cutout
.250 R
1
(6.351 R
9.531
{242. 0 0)
I
I
-
f -
14. 6 88
]
I I
1
5.156
{130.9
2 1
.250 (6.35) Tap o r
.313 (7.93) Dia.
141 Holes
Plug-In Adapter Kit
Poles
Ampere
Kit Styl e
Thread
Rating
Number
Size
125-400
313C644G25
.750 (19.041 - 16 (406.24)
125-400
313C644G26
.750 (19.041 - 16 (406.24)
Do Not Use More Than 25 Ft.
Lbs. Torque to Tighten Nuts
Reproduced from drawing 1371033
Dimensions in parentheses in millimeters