Brush Motor Carbon Brushes Checking/Replacing - Nilfisk-Advance SCRUBTEC 344 Series Service Manual

Hide thumbs Also See for SCRUBTEC 344 Series:
Table of Contents

Advertisement

Service Manual – SC401, SCRUBTEC 344

Brush Motor Carbon Brushes Checking/Replacing

Check
1
Remove the brush deck
2
Remove any dust and dirt from around the brush motor carbon brushes
3
Remove the four protective covers (A) (Figure 11) by disconnecting the clips
4
Remove the carbon brush nuts (B) with the lead-in wires
5
Disengage the tabs (C) and remove the carbon brushes (D)
6
Check the carbon brushes (D) for wear The carbon brushes are worn out when:
◦ They do not make sufficient contact with the armature of the brush motor due to their wear
◦ When their contact surface is not intact
◦ When the residual stroke is below 0 12 in (3 mm)
◦ When the thrust spring etc is broken
7
Replace the carbon brushes as an assembly
Replacing
8
Assemble the components in the reverse order of disassembly
A
Figure 9:
A
B
34 - Scrub System, Disc
D
C
C