Load Range .......5 Ω to 2M Ω
Output Power .....Up to 3 Watts (Low,
Output Voltage ...5 Volts - 600 Volts
Power Supply .....8 × C (R14) Cell
Battery Life.........Continuous: up to 15 hours,
Operating
Temperature .......-4°F to 133°F
Storage
Temperature.......-13°F to 140°F
IP Rating ............IP54
Size....................8.5" x 5.8" x 2.5"
Weight................2.2 lbs. (1 kg)
Test Lead
Jacks..................0.16" (4mm) as per
FR-30 A-Frame Receiver:
Operating
Frequencies .......Fault Finding:
Fault Finding
Depth .................Up to 20' (6m) (depend-
Fault Finding
Length................Up to 3 miles (4800 m)
Display ...............Black and White LCD
Audio
Indication ...........Piezo Response
6
Find Quality Products Online at:
A-Frame Fault Locator
Path locating:
128 Hz, 1 kHz, 8 kHz, 33
kHz, 93 kHz
Direct Connect:
128 Hz, 1 kHz, 8 kHz, 33
kHz, 93 kHz
Inductive Clamp:
8 kHz, 33 kHz, 93 kHz
Broadcast Inductive:
33 kHz, 93 kHz
medium and high settings)
Batteries, 12 Volt
Intermittent: up to 60 hours
(on low at 1000 Ohm load)
(-20°C to 55°C)
(-25°C to 60°C)
(21 cm x 15 cm x 6 cm)
IEC61010
797 Hz - "dFF" displayed
Direct Connect:
ing on conditions)
(depending on conditions)
GlobalTestSupply
www.
Power Supply .....6 × AA (LR6) Batteries,
9 Volt
Battery Life..........Continuous: up to 40 hours,
Intermittent: up to 82 hours
Operating
Temperature .......-4°F to 133°F
(-20°C to 55°C)
Storage
Temperature.......-13°F to 140°F
(-25°C to 60°C)
IP Rating ............IP54
Size....................30.3" x 30.4" x 1.5"
(77 cm x 77 cm x 4 cm)
Weight................3 lbs. (1.3 kg)

Standard Equipment

The A-Frame Fault Locator package includes
the following items:
• FR-30 A-Frame Receiver
• FT-103 Transmitter
• Ground Stake
• Red and Black Test Leads (7 .5' (2.3 m) long)
• Carry Cases
• Batteries
• Operator's Manual Pack
NOTICE
This equipment is used for conduc-
tor fault and path locating. Incorrect use or
improper application may result in incorrect or
inaccurate locating. Selection of appropriate lo-
cating methods for the conditions and proper
operation is the responsibility of the user.
Changing/Installing
Batteries
WARNING
Switch unit OFF and remove any con-
nections from the Transmitter/Receiver
before changing batteries.
The A-Frame Fault Locator is supplied without
the batteries installed. Remove the batteries
prior to storage to avoid battery leakage. When
the low battery indicator appears on the trans-
mitter (
) or receiver (
teries need to be replaced.
NOTICE
Use the batteries that are of same
type. Do not mix battery types. Do not mix
new and used batteries. Mixing batteries can
cause overheating and battery damage.