Wiring Diagram - Daikin FXFQ-PVE9 Series Technical Data Manual

Round flow cassette
Table of Contents

Advertisement

7

Wiring diagram

7 - 1 Wiring diagram
FXFQ-PV9
POWER SUPPLY
CONTROL BOX
Indoor unit
A1P
Printed circuit board
A2P
Printed circuit board
C1
Capacitor
F1U
Fuse (F, 5A, 250V)
HAP
Light emitting diode (service monitor green)
K1R
Magnetic relay
KPR
Magnetic relay (M1P)
M1F
Motor (indoor fan)
M1P
Motor (drain pump)
M1S
Motor (swing flap)
R1T
Thermistor (AIR)
R2T
Thermistor (coil liquid)
R3T
Thermistor (coil gas)
: Terminal
,
: Connector
: Field wiring
NOTES
1
In case of using central remote control, connect it to the unit in accordance with the attached instruction manual.
2
X24A, X33A and X35A are connected when the optional accessories are being used.
3
When connecting the input wires from outside, forced off or on/off control operation can be selected by the remote control. See installation manual
for more details.
4
Confirm the method of setting the selector switch (SS1, SS2) by installation manual and engineering data, etc.
• Indoor Units • Round Flow Cassette • FXFQ-PVE9
R4T
Thermistor PTC
S1L
Float switch
V1R
Diode bridge
X1M
Terminal strip
X2M
Terminal strip
Y1E
Electronic expansion valve
Z1C
Ferrite core
Z1F
Noise filter
Power supply circuit
PS
Receiver/display unit (attached to infrared remote control)
A3P
Printed circuit board
A4P
Printed circuit board
BS1
Push button (ON/OFF)
H1P
Light emitting diode (on-red)
Colors:
RED:
Red
BLK:
Black
WHT:
White
YLW:
Yellow
®
• VRV
Systems • Indoor Units
note 3
note 3
note 4
-CLASS
H2P
H3P
H4P
SS1
SS2
X24A
X33A
X35A
R1T
SS1
GRN:
Green
ORG: Orange
BRN:
Brown
PNK:
Pink
Receiver/display unit
Input from outside (note 4)
Transmission wiring
Central remote control (note 2)
Wired remote control
-CLASS
Light emitting diode (timer-green)
Light emitting diode (filter sign-red)
Light emitting diode (defrost-orange)
Selector switch (main/sub)
Selector switch (wireless address set)
Connector for optional parts
Connector (wireless remote control)
Connector (adaptor for wiring)
Connector (group control adaptor)
Wired remote control
Thermistor (AIR)
Selector switch (main/sub)
GRY:
Gray
BLU:
Blue
3D059890A
3
1
7
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents