Initilize Ic (Reset Circuit); Power Down Detection Circuit (Pwd); Address Latch Circuit - Casio PCR-365A Service Manual

Table of Contents

Advertisement

5-4. Initilize IC (Reset circuit)

When the voltage level at Pin No.60 of CPU is not stabilized, CPU does not work properly in rare case.
Therefore, this machine uses the initialize IC for stabilizing the voltage.
Even the voltage level of VDD (Pin No.2) is changed, Pin No.1 of initilize IC outputs stabilized 5 volts.
When the VDD voltage become less than 1.9 V, the initialize IC send a reset signal to CPU.

5-5. Power down detection circuit (PWD)

When the VP voltage become less than 4.8 V, the pin No.1 of IC5 become "Low" level.
Then,the transistor Q44 become OFF.
When Q44 become OFF, the voltage lebel of pin No.64 of CPU changes to "High" level from "Low". Then,
CPU knows power failure.

5-6. Address latch circuit

VDD: Voltage of memory protection battery
To Pin No.60 of CPU
To Pin No.64 of CPU
— 11 —
CPU uses 8 port (AD0 ~ AD7) for
address bus and data bus.
To select the address, CPU use the
IC13.
CPU send the address to IC13, and
send ASTB signal at same time.
Then, IC13 store the address and
output the address immediately.
In this way, CPU select the address
and data signal.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ce-200Ce-250

Table of Contents