IN-LINE BLOWER
For use with models CTWH30, CTWH36,
I
W30-662718,
36-663418, L34-582212
READ AND SAVE THESE INSTRUCTIONS
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer or your dis-
tributor.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service discon-
necting means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a quali-
fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Con-
ditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only steel ductwork.
8. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to
a GFCI (Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when
flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Pepper-
corn Beef Flambe').
3. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOW-
ING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal
tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - vio-
lent steam explosion will result.
FOR DOMESTIC COOKING ONLY
MODEL 808332
I
H4227, DD30R, DD36R, W30-662418,
WARNING
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already
know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. If ventilator is installed in an unconditioned space (such as
an attic): Surround the ventilator with thermal insulation - to
minimize possible condensation.
4. Please read specification label on product for further informa-
tion and requirements.
TABLE OF CONTENTS
This manual is divided into sections as follows:
"TYPICAL INSTALLATION"
This section shows a common installation.
- Mounting (New Frame Construction)
- Mounting (Existing Frame Construction)
- Mounting Using Hanger Kit (included)
- Ducting (Horizontal blower discharge)
- Wiring
"MOUNTING OPTIONS"
"WIRING PLATE POSITION"
"DUCTING OPTIONS"
- Blower Discharge Positions
- Ducting (Vertical blower discharge)
"USE AND CARE"
Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 4.
Page 1
!

Advertisement

Table of Contents
loading

Summary of Contents for Wolf 808332

  • Page 1 MODEL 808332 Page 1 IN-LINE BLOWER For use with models CTWH30, CTWH36, H4227, DD30R, DD36R, W30-662418, W30-662718, 36-663418, L34-582212 READ AND SAVE THESE INSTRUCTIONS FOR DOMESTIC COOKING ONLY WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- 4.
  • Page 2: Typical Installation

    Page 2 TYPICAL INSTALLATION TYPICAL INSTALLATION MOUNTING USING HANGER KIT (included) MOUNTING (New Frame Construction) 10” ROUND DUCT 8” X 12” TO (OUTLET) HANGER 10” ROUND KIT BOLT TRANSITIONS & WASHER EXTENSION SPRING 10” ROUND DUCT HANGER 10” ROUND (INTAKE) KIT CHAIN DUCT (INTAKE) HANGER KIT...
  • Page 3: Mounting Options

    Page 3 WIRING PLATE POSITION WIRING BLACK BLACK EDGE OF HOUSING VERTICAL GROUND TO POWER WIRING PLATE CABLE CONNECTION WIRING PLATE HORIZONTAL POWER CABLE CONNECTION Wiring plate mounts to side or top of housing. WHITE WHITE 120 VAC LINE IN (from range hood) DUCTING OPTIONS Ventilator can be wired from outside of housing.
  • Page 4 Page 4 USE AND CARE Follow wiring instructions packed with range hood, and adhere to all local and state codes, and the National Electrical Code. WARNING: To reduce the risk of electric shock, disconnect from power supply before servicing. To clean blower assembly: Remove access panel, unplug blower from housing, remove blower mounting nuts, and carefully remove blower from housing.
  • Page 5 Page 5 MODÈLE 808332 VENTILATEUR MONTAGE DANS LIGNE Pour usage avec modèles CTWH30, CTWH36, I H4227, DD30R, DD36R, W30-662418, W30-662718, I 36-663418, L34-582212 LIRE ET CONSERVER CES INSTRUCTIONS POUR USAGE DOMESTIQUE SEULEMENT AVERTISSEMENT AVERTISSEMENT mouillés car cela peut provoquer une violente explosion de vapeur.
  • Page 6: Installation Typique

    Page 6 INSTALLATION TYPIQUE INSTALLATION TYPIQUE MONTAGE (Construction en cours) MONTAGE EN UTILISANT LE KIT DE CINTRE (inclus) CONDUIT CIRCULAIRE DE 10 po (25,4 cm) (sortie) TRANSITION DE 8 x 12 po au VIS ET 10 po circulaire (20,3 x 30,5 cm au RONDELLE DE 25,4 cm circulaire) LE KIT POUR...
  • Page 7: Options De Montage

    Page 7 POSITION DE LA PLAQUE DE CÂBLAGE CÂBLAGE NOIR AU DESSUS / NOIR ARRIÈRE DU BOÎTIER FIL DE TERRE À PLAQUE DE CÂBLAGE BRANCHEMENT PLAQUE DU CÂBLE D’ALIMENTATION CÂBLAGE À LA VERTICALE ENTRÉE BRANCHEMENT DU 120 VCA CÂBLE D’ALIMENTATION BLANC (du le hotte) À...
  • Page 8: Utilisation Et Entretien

    Page 8 UTILISATION ET ENTRETIEN Suivre les instructions de câblage fournies avec le hotte et respecter tous les codes locaux et provinciaux en vigueur, de même que le Code national de l’électricité. AVERTISSEMENT : Pour diminuer les risques de décharge électrique, débrancher la source d’alimentation avant toute opération d’entretien.