DUCTING TO WHOLE HOME WITHOUT AN AIR HANDLER
In this installation the dehumidifier is not ducted to the HVAC system�
FIGURE 11 – STAND ALONE DUCTED
REQUIRED COMPONENTS:
• 10" Ductwork
DEHUMIDIFIED AIR IS SUPPLIED TO DUCTED SPACE
• Grilles with 10" Duct Collars
DEHUMIDIFIED SPACE
10' MIN
AIR IS PULLED FROM
DUCTED SPACE
DEHUMIDIFIER
GRILLE WITH 10" DUCT COLLAR (2 PLACES)
90-2026
8