11.03
REF1 SELECT
16.04
FAULT RESET
SEL
(11.05)
REF1 MAX
ACS550 More actual values or parameters to be read from drive to PLC
(optional)
Parameter
Description
51.06,
Actual value or
51.08...
parameter of drive
51.20
51.27
FBA PAR
REFRESH
ACS550 More parameters to be written from PLC to drive (optional)
Parameter
Description
51.05,
Parameter of drive
51.07...
51.19
51.27
FBA PAR
REFRESH
COMM
COMM
[Scale max]
Setting
Comment
GGii
GG = parameter group, ii = parameter index
Example, 0104 = actual current; 0145 = motor temp
REFRESH
Updates fieldbus settings (group 51)
Setting
Comment
GGii
GG = parameter group, ii = parameter index
Example, 2202 = acceleration time 1
REFRESH
Updates fieldbus settings (group 51)
Fieldbus interface as source for speed
reference
Fieldbus interface as source for fault
reset
Max speed/frequency scaling value
(used in function block/visualization input
SPEED_REF_MAX). Must be less or
equal to drive parameter max
speed/frequency.