Component Failure Evaluation in 24 Volt Mode
Door panel has
yellow or red
flashing LEDs
Power the air
cleaner with
24VAC and
establish a "G"
call from T-Stat
Door operates
correctly
Turn power off,
Remove the power
door, install the
collection cells, and re-
install the power door
The power door
and collection
cells operate
correctly
Turn power off,
Remove the power
door, install the field
charger, and re-install
the power door
Air cleaner is
operating
correctly
EAC-SF-13
Remove the
power door,
collection cells,
and field charger
Bypass the 10 minute
time delay (This is
done by entering and
exiting the set-up
mode)
Does Green Led #1
Yes
begin to flash slowly
Power the air
cleaner with
24VAC and
establish a "G"
call from T-Stat
Does Green Led #1
Yes
begin to flash slowly
Power the air
cleaner with
24VAC and
establish a "G"
call from T-Stat
Does Green Led #1
Yes
begin to flash slowly
Numbers in [brackets] are for 50 Hz international systems.
Service Facts
No
Bypass the 10 minute
time delay (This is
done by entering and
exiting the set-up
mode)
No
Bypass the 10 minute
time delay (This is
done by entering and
exiting the set-up
mode)
No
Reinstall power
door to air cleaner
Wait 10 seconds
Replace the
power door
Wait 10 seconds
Replace both
collection cells
Wait 10 seconds
Replace the field
charger