Advertisement

Room Air Conditioner
OWNER'S MANUAL
WINDOW TYPE ROOM AIR CONDITIONER
• Please read carefully and thoroughly this manual
before operating this unit.
• Contact the authorized SVC man for repair or
maintenance of this unit.
• Contact the installer for installation of this unit.
• The appliance is not intended for use by young children or
infirm persons without supervision.
• Young children should be supervised to ensure that they do
not play with the appliance.
MODELS : LWC1260ACG/ LWC1260BCG
LWC1260PCG
LWC0960AHG/ LWC0960PHG
LWC1260AHG/ LWC1260PHG
LWC1262ACG/ LWC1262BCG
LWC1262PCG
LWC1262AHG/ LWC1262PHG
ENGLISH ..................... P.1 - P.12
ITALIANO .................. P.13 - P.24
ESPAÑOL .................. P.25 - P.36
FRANÇAIS ................. P.37 - P.48
DEUTSCH .................. P.49 - P.60
Prior to installation, this air-conditioning unit must be
submitted for approval by the utility service which
provides electricity (EN 61000-3 Norm).

Advertisement

Table of Contents
loading

Summary of Contents for LG LWC1260ACG

  • Page 1 • The appliance is not intended for use by young children or infirm persons without supervision. • Young children should be supervised to ensure that they do not play with the appliance. MODELS : LWC1260ACG/ LWC1260BCG LWC1260PCG LWC0960AHG/ LWC0960PHG LWC1260AHG/ LWC1260PHG...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SAFETY PRECAUTIONS ..................2 FEATURES ........................ 5 OPERATING ......................6 FUNCTION ......................6~8 HOW TO INSERT BATTERIES ................8 VENTILATION ......................9 TO CONTROL AIR DIRECTION ................9 AIR FILTER CLEANING ..................10 HOW TO COMBINE FRONT GRILLE WITH CABINET ........10 INSTALLATION .......................
  • Page 3 Operation precautions WARNING Plug in the power plug Do not operate or stop the unit Do not damage or use an by inserting or pulling out the properly. unspecified power cord. power plug. • Otherwise, it will cause electrical • It will cause electrical shock or fire •...
  • Page 4 CAUTION When the air filter is to be Do not clean the air Ventilate well when used conditioner with water. removed, do not touch the together with a stove, etc. metalparts of the unit. • It may cause an injury. •...
  • Page 5: Features

    FEATURES VERTICAL AIR DEFLECTOR (HORIZONTAL LOUVER) HOROZONTAL AIR DEFLECTOR (VERTICAL LOUVER) CABINET AIR DISCHARGE FRONT GRILLE AIR INTAKE AIR FILTER (INLET GRILLE) BRACE CONDENSER BASE PAN EVAPORATOR CONTROL BOARD COMPRESSOR POWER CORD ENGLISH...
  • Page 6: Operating

    OPERATING CAUTION When the air conditioner has been performing its cooling operation and is turned off or set to the fan position, wait at least 3 minutes before resetting to the cooling operation again. FUNCTION • THERMOSTAT • OPERATION Thermostat will automatically control the O : Turns the air conditioner off.
  • Page 7 Heater Warmer Cooler Thermostat Operation • THERMOSTAT • OPERATION Turn the thermostat control to the desired : Turns the air conditioner off. setting. The centrol position is a normal setting : Permits the low fan speed operation for average conditions. You can change this without cooling(heating).
  • Page 8: How To Insert Batteries

    REMOTE CONTROL POWER BUTTON Operation starts, when this button is pressed and stops when you press the button again. OPERATION MODE SELECTION BUTTON Select Cooling, Heating, or Fan mode with this button. ON/OFF TIMER BUTTON Set the time of starting and stopping operation. The timer is set by 1 hour.
  • Page 9: Ventilation

    VENTILATION The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions. When fresh air is necessary in the room, set the ventilation lever to the OPEN position. The damper is opened and room air is exhausted. Part Ⓑ...
  • Page 10: Air Filter Cleaning

    AIR FILTER CLEANING The air filter should be checked at least twice a month to see if cleaning is necessary. Trapped particles in the filter will build up and block the airflow. This reduces the cooling capacity and also causes an accumulation of frost on the cooling coils. 1.
  • Page 11: Installation

    INSTALLATION If a power plug is not to be used, provide a circuit breaker between power source and the unit as shown below. Main power source Circuit Breaker Use a circuit breaker or time delay fuse. FENCE AWNING COOLED AIR HEAT RADIATION BASE PAN ABOUT 10mm...
  • Page 12: Before Requesting Service

    HOW TO ATTACH DRAIN PAN The air conditioner employs a proper drain method whereby the condensate water (moisture removed from the air) is drained to the outside. In very humid weather, (and for reverse cycle models in the reverse mode) excessive condensate water removed from the air may cause some water to collect.
  • Page 13 P/NO.: 3828A20049B Printed in Korea...