"C" Programming Guide For Optimus S/R
Note: Only one network interface can be used at a time: 802.11b or PAN
Parameter
int DhcpEnable
unsigned char IpAddr[4]
unsigned char SubnetMask[4]
unsigned char
DefaultGateway[4]
unsigned char DnsServer[4]
char DomainName[129]
char LocalName[33]
char SSID[33]
int SystemScale
unsigned int WLAN_FLAG
int WepLen
int DefaultKey
unsigned char WepKey[4][14] Null
char EapID[33]
char EapPassword[33]
char ReservedByte[100]
Default
Description
1
0: disable DHCP
1: enable DHCP
0.0.0.0
Local IP Address
0.0.0.0
Subnet Mask
0.0.0.0
IP address of Default
Gateway or router
0.0.0.0
IP address of DNS server
Null
Domain Name
S/N
Local host name.
By default, it shows the serial
number of terminal.
Null
Service Set ID or AP name,
which is used for Remote
Device association.
2
Access Point Density,
determines when the terminal
should look for other AP that
has better signal strength.
1: Low
2: Medium
3: High
0x19
See WLAN_FLAG Structure
1
0: 64 bits Wep Key
(5 bytes to be configured for
the WepKey parameter)
1: 128 bits Wep Key
(13 bytes to be configured for
the WepKey parameter)
0
Use default Wep Key 0
WEP Key 0 ~ 3
Null
ID to login EAP system
Null
Password to login EAP
system
Null
Reserved