Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
CONVECTION FAN MOTOR
Refer to page 4-13 for the procedure for servic-
ing the convection fan motor.
1.
Unplug range or disconnect power.
2.
Disconnect one of the wires from the con-
vection fan motor terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
convection fan motor terminals. The meter
should indicate between 14 and 22 Ω.
WARNING
Electrical Shock Hazard
COOLING FAN MOTOR
Refer to page 4-15 for the procedure for servic-
ing the cooling fan.
1.
Unplug range or disconnect power.
2.
Disconnect one of the wires from the cool-
ing fan motor terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
cooling fan motor terminals. The meter
should indicate between 11 and 17 Ω.
5-6