LG Multi V ARNU093TUD4 Engineering Manual page 56

Ceiling cassette indoor unit; one-way ceiling cassettes; two-way ceiling cassettes; four-way ceiling cassettes
Hide thumbs Also See for Multi V ARNU093TUD4:
Table of Contents

Advertisement

FOUR-WAY CEILING CASSETTE
General Data
Table 26: Four-Way Ceiling Cassette (2' x 2' TR and TQ Frames) Indoor Unit General Data.
Model No.
Capacity (Btu/h)
Power Input
(W)
1
Capacity (Btu/h)
Power Input
(W)
1
Cooling Max. (°F WB)
Heating Min. (°F DB)
Refrigerant Type
2
Refrigerant Control
Sound Pressure
dB(A) (H/M/L)
3
Net Unit Weight (lbs.)
Shipping Weight (lbs.)
Grille Weight (lbs)
Grille Shipping Weight (lbs)
Communication Cable
4
(No. x AWG)
Type
Quantity
Motor/Drive
Airflow Rate H/M/L (CFM)
Liquid Line (in., O.D.)
Vapor Line (in., O.D.)
Condensate Line (in., I.D.)
EEV: Electronic Expansion Valve
Power wiring is field supplied and must comply with the applicable local and national codes. See page
61 for detailed electrical data.
This unit comes with a dry nitrogen charge.
All capacities are net with a combination ratio between 95-105%.
Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice.
Current certified ratings are available at www.ahridirectory.org.
56 | FOUR-WAY
ARNU053TRD4 ARNU073TRD4 ARNU093TRD4 ARNU123TRD4 ARNU153TQD4 ARNU183TQD4
5,500
7,500
30
30
6,100
8,500
30
30
76
76
59
59
R410A
R410A
EEV
EEV
29 / 27 / 26
29 / 27 / 26
29
29
34
34
7
7
11
11
2 x 18
2 x 18
Turbo
Turbo
1
1
265 / 247 / 212
265 / 247 / 212
1/4 Flare
1/4 Flare
1/2 Flare
1/2 Flare
1
1
©
9,600
12,300
30
30
10,900
13,600
30
30
76
76
59
59
R410A
R410A
EEV
EEV
30 / 29 / 27
32 / 30 / 27
32
32
38
38
7
7
11
11
2 x 18
2 x 18
Turbo
Turbo
1
1
Brushless Digitally Controlled / Direct
283 / 265 / 251
307 / 283 / 247
1/4 Flare
1/4 Flare
1/2 Flare
1/2 Flare
1
1
Power Input is rated at high speed.
1
Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or destroy
2
R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F) under section 608
of CAA.
3
Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
Communication cable between Master ODU to IDUs / HRUs to be 18 AWG, 2-conductor, twisted,
4
stranded, shielded. Ensure the communication cable shield is properly grounded to the Master ODU
chassis only.
Do not ground the ODU to IDUs / HRUs communication cable at any other point.
Wiring must comply with all applicable local and national codes.
15,400
19,100
30
30
17,100
21,500
30
30
76
76
59
59
R410A
R410A
EEV
EEV
36 / 34 / 32
37 / 35 / 34
35
35
40
40
7
7
11
11
2 x 18
2 x 18
Turbo
Turbo
1
1
388 / 353 / 328
396 / 388 / 353
1/4 Flare
1/4 Flare
1/2 Flare
1/2 Flare
1
1