Download Print this page
Hilti HIT-HY 200 HIT-Z Product Data Sheet
Hilti HIT-HY 200 HIT-Z Product Data Sheet

Hilti HIT-HY 200 HIT-Z Product Data Sheet

Injection mortar system

Advertisement

Quick Links

Hilti HIT-HY 200 with HIT-Z
Injection Mortar System
A4
316
Concrete
Tensile
Corrosion
zone
resistance
Basic loading data (for a single anchor)
All data in this section applies to
Correct setting (See setting instruction)
No edge distance and spacing influence
Steel failure
Base material thickness, as specified in the table
Embedment depth, as specified in the table
Embedment depth and base material thickness for the basic loading data
Recommended loads
Anchor size
Typical embedment depth h
Base material thickness h [mm]
Recommended loads
Anchor HIT-Z
Anchor size
Tensile N
[kN]
rec
Shear V
[kN]
rec
Note: For varied embedment depths please contact your local Hilti engineer for further details.
page 1
European
CE
PROFIS
Technical
conformity
anchor design
Approval
software
[mm]
ef
Hilti HIT-HY 200-R
500 ml foil pack
(also available as 330 ml
foil pack)
Static mixer
HIT-Z
HIT-Z-R rod
No cleaning
Seismic
Diamond
required for
drilled
approved
holes
loads
One anchor material, as specified in the tables
Non cracked concrete f
Temperate range I (min. base material temperature -40°C, max.
long term/short term base material temperature: +24°C/40°C)
Installation temperature range -10°C to +40°C
M8
M10
80
90
140
150
M8
M10
11.4
18.1
6.9
10.9
Product Data Sheet
HIT-HY 200
with HIT-Z
Benefits
no cleaning required: zero
succeptability to borehole cleaning
conditions with dry and water
saturated concrete base material
maximum load performance in
cracked concrete and uncracked
concrete
suitable for cracked and non-cracked
concrete C 20/25 to C 50/60
suitable for use with diamond cored
holes in non-cracked or cracked
concrete with no load reductions
= 32 MPa
c,cyl
M12
M16
110
145
170
245
M12
M16
25.9
45.7
15.4
27.4
M20
180
280
M20
69.5
41.7
February 2014

Advertisement

loading

Summary of Contents for Hilti HIT-HY 200 HIT-Z

  • Page 1 Base material thickness h [mm] Recommended loads Anchor HIT-Z Anchor size Tensile N [kN] 11.4 18.1 25.9 45.7 69.5 Shear V [kN] 10.9 15.4 27.4 41.7 Note: For varied embedment depths please contact your local Hilti engineer for further details. page 1 February 2014...
  • Page 2: Approvals / Certificates

    Product Data Sheet HIT-HY 200 with HIT-Z Approvals / certificates Description Authority / Laboratory No. / date of issue ETA-12/0028 / 2013-03-15 European technical approval DIBt, Berlin (HIT-HY 200-R) Fire test report IBMB, Brunswick 3501/676/13 / 2012-08-03 a) All data given in this section according ETA-12/0028, issue 2013-03-15. Working time, curing time HIT-HY 200-R Temperature of the base material...
  • Page 3: Material Quality

    Product Data Sheet HIT-HY 200 with HIT-Z Materials Mechanical properties of HIT-Z and HIT-Z-R Anchor size HIT-Z Nominal tensile strength f [N/mm²] HIT-Z-R HIT-Z Yield strength f [N/mm²] HIT-Z-R Stressed cross-section A HIT-Z [mm²] 36.6 58.0 84.3 Moment of resistance W HIT-Z [mm³] 31.9...
  • Page 4 Product Data Sheet HIT-HY 200 with HIT-Z Setting instructions Bore hole drilling Pre-setting: Drill hole to the required drilling depth with a hammer drill set in rotation-hammer mode using an appropriately sized carbide drill bit. Diamond coring is permissible when diamond core drilling machine and the corresponding core bit are used.
  • Page 5: Overhead Installation

    Setting instructions Injection preparation Tightly attach new Hilti mixing nozzle HIT-RE-M to foil pack manifold (snug fit). Do not modify the mixing nozzle. Observe the instruction for use of the dispenser. Check foil pack holder for proper function. Do not use damaged foil packs / holders.