Model
Power/Current
Refrigerant
Cooling Capacity
Heating Capacity
JIS C 9612
[<70 dB(A)]
Conditions 1m
Noise Level
Distance
Max. cooling/
heating
operation
Air Circulation
Product Weight
kg
Dimensions (H x W x D)
• Standby power consumption ≤ 0.9w (when switched OFF by remote control, except under self-
protection control).
• Standard piping length: 7.5m.
• Air filters are attached.
18
F568623(F568899)-en.indd 18
CS-RE9PKV-7
CU-RE9PKV-7
COOL
Single, 220V,60Hz
[kW]
0.780
[A]
3.80
R410A
[kg]
0.780
[kW]
2.64
[kW]
2.93
40
[dB(A)]
47
3
[m
/min.]
12.5
8.0
[kg]
283×803×214
[mm]
540×780×289
CS-RE12PKV71
CU-RE12PKV71
HEAT
COOL
Single, 220V,60Hz
0.740
1.040
3.60
5.10
R410A
40
42
48
48
13.0
13.5
22
283×803×214
540×780×289
HEAT
1.060
5.10
0.850
3.52
4.10
42
50
13.9
8.0
26.5
2013-11-5 15:43:41