  • Page 2: Foreword

    Foreword: The purpose of this document is to describe how to install and configure the Neets Control - ZULU. COPYRIGHT - All information contained in this manual is the intellectual property of and copyrighted material of Neets. All rights are reserved. You may not allow any third party access to content, information or data in this manual without Neets’...
  • Page 3: Table Of Contents

    Table of content Foreword: ......................1 Revision list: ......................1 Table of content ..................... 2 Description: ......................3 Connections on units ..................... 4 Technical description ..................... 5 USB ................................5 Power output ..............................5 Time Battery (RTC) ............................5 RS-232 Port ..............................6 IR/RS-232 ports .............................
  • Page 4: Description

    Description: Neets Control - ZULU is the biggest system in the Neets product portfolio and the first control system in the new generation of Neets control systems. The system can be controlled via web browser (IPhone, IPod Touch, table PC etc.).The system has a LAN connection making this feature possible. All it requires is a wireless access point.
  • Page 5: Connections On Units

    Connections on units Number Description 1: Extern 12V DC out 2: Fuse to enable screen mode on RELAY 1 and RELAY 2 (13) 3: RS-232 port 4: RS-232 or IR control out 5: 230 VAC power in 6: Relay connectors 7: LED and relay test button 8: Input/Output 9: Mini USB...
  • Page 6: Technical Description

    Maximum screen size (recommended) 2,5 meters The USB port can only be used to program the Neets Control – ZULU from the Neets Project designer software. It cannot be used to control any devices what so ever. From the USB you can also power the system (except 12VDV/350mA out and the onboard relays, those two things will not work).
  • Page 7: Rs-232 Port

    RS-232 port, or any USB to RS-232 converter. IR/RS-232 ports The Zulu has 4 ports (TX-2, TX-3, TX-4 and TX-5) that can be configured (in software) either as RS-232 or as IR emitter. Junction PIN 5 <->...
  • Page 8: Switch And Led

    Press, and hold all 4 switch for 5 seconds (until all 4 LED flashes fast) I/O Ports The Neets Control – ZULU has 24 i/o’s onboard. They can be used for external keyboard, PIR (movement) sensor, Keyboard lock, extra relays and so on.
  • Page 9: Onboard Relays

    When using the 4 relays you can select what type of voltage you want to use at installation time. The flexibility of the Neets Control - ZULU offers you the possibility to control high voltage or low voltage (Please note that high and low voltage cannot be used simultaneously).
  • Page 10: Cable In/Out Of The Box

    Cable in/out of the box The Neets Control - ZULU box comes with rubber globs. This allows you to use any cable size you want, and the taps inside the box gives you a good and flexible way of safely fixating the cable.
  • Page 11: Fault Finding

    Fault finding When errors occur the LED will indicate this. The following will give you a guide to find these errors. In the Neets Control – ZULU the LED´s are placed here: Fault Solution SD card missing Control that the SD card is mounted correctly and that the uSD card that you are using are formatted with FAT.
  • Page 12: System Log File

    This method are only intended to be used if the control system lock up and enter “Unexpected Error” System log file The Neets Control – ZULU has a log file, which contains information, warning and error that the system encounters during run. The log file looks like below.