ABB Tina 10A Original Instructions Manual page 11

Adaptor unit
Hide thumbs Also See for Tina 10A:
Table of Contents

Advertisement

Safety / Harmonized Standards
Conformity
IEC/EN 61508-1...7
EN 62061
EN ISO 13849-1
Certificates
Information for use in USA/Canada
Power source
Certificate
Pollution degree
Altitude
Humidity
Electrical supply
Indoor use statement
Temperature
2TLC010042M0201 rev.B
European Machinery Directive 2006/42/EC
EN ISO 12100:2010, EN 60204-1:2006+A1:2009, EN 62061:2005+A2:2015,
EN ISO 13849-1:2015, EN 61496-1:2013
-9
SIL3, PFH
= 4.50·10
D
SIL3
Performance level: PLe, category 4
TÜV Nord
A suitable isolating source must be used in conjunction with a fuse in accordance with
UL248. The fuse must be rated max. 4 A and installed in the +24 VDC power supply,
to limit the available current.
2
2000 m (max)
80% max for temperatures up to 31°C
24 VDC, 25 mA
For indoor use only
-10 to 55°C
11
www.abb.com/jokabsafety

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tina 10bTina 10c

Table of Contents