Dometic HiPro Series Installation And Operating Manual page 27

Minibar
Hide thumbs Also See for HiPro Series:
Table of Contents

Advertisement

HiPro
Fault
No cooling, absorber
unit warm
No cooling, interior
light and door opening
monitor (optional) flash
continuously
Poor cooling perfor-
mance
Frost formation in the
refrigerator compart-
ment
EN
Possible cause
Refrigerator is not level
Refrigerator was only switched on
recently
Cooling unit is defective
Refrigerator is not level
Cooling unit blocked
Cooling unit not water-tight
Heating element defective
Error during self-test
Cooling unit not sufficiently ventilated Bring about sufficient ven-
Refrigerator is exposed to direct sun-
light
Door of refrigerator does not close
with a tight seal
Refrigerator was recently filled
Door of refrigerator does not close
with a tight seal
Troubleshooting
Solution
Align refrigerator with
water level
Check cooling again after
5 to 6 hours
Authorized service:
Replace refrigerator
Align refrigerator with
water level
Contact authorized cus-
tomer service
tilation (fig. 3, page 5)
Take refrigerator out of
direct sunlight
Check distances (fig. 0,
page 9)
Authorized service:
Replace door seal
Check cooling again after
5 to 6 hours
Check distances (fig. 0,
page 9)
Authorized service:
Replace door seal