Advertisement

Hardware description
A.2 Internal interfaces
A.2.2

SCSI activity connector

Type JST B2B-PH-SM3-TB
Pin
1
2
A.2.3

Reset

Type JST B2B-PH-SM3-TB
NOTICE
Observe safety information
Only use this interface for maintenance purposes. You should observe the warnings in
"Open the device (Page 89)".
Pin
1
2
A.2.4

Power button

Type JST B2B-PH-SM3-TB
NOTICE
Observe safety information
Only use this interface for maintenance purposes. You should observe the warnings in
"Open the device (Page 89)".
Pin
1
2
174
Name
Meaning
NC
-
SCSI HD_N
0-V level means that the SCSI interface is active
Name
Meaning
GND
Ground
Reset
Input, 0 V level means reset
Name
Meaning
EXT_PWRBTN
Input, 0 V level means Power button pressed
GND
Ground