RM-869
5-3. A BOARD ADJUSTMENT AFTER IC003
(MEMORY) REPLACEMENT
1. Enter to Service Mode.
2. Press commander buttons 5 and - (Data Initialize), and 2
and - (Data Copy) to initialize the data.
3. Call each item number, and check if the respective screen shows
the normal picture.
In case some items are not well-adjusted, give them fine
adjustment.
Write the data per each item number (
4. Select item numbers "3E" (OP0), "3F" (OP1) and "40" (OP2)
and respectively set the bit per model with command buttons
3 and 6.
5. Press commander buttons 8 and - (Test Normal) to return
to the data that was set on the shipment from the factory.
(= Cancel Service Mode.)

5-4. PICTURE DISTORTION ADJUSTMENT

Item Number 00 – 08
00
01
02
+ -).
MUTING
03
04
05
06
07
08
– 22 –
HSF (H SHIFT)
HSZ (H SIZE)
PAP (PIN AMPLITUDE)
CNP (CORNER PIN)
TLT (TILT)
VSL (V SLOPE)
VAP (V AMPLITUDE)
SCR (S CORRECTION)
VSF (V SHIFT)