Pigi 5·4.
Tlbll 5·3. Replace
Tolerances. with Table MC1 of this Change Sheet.
1 Millivolt Ringe Only
Frequlncy
1%
(Hz)
Voltlge
Input
10
1.00 mV
1.00
0.5 mV
0.50
0.3 mV
0.30
40
1.00 mV
1.00
0.5 mV
0.50
0.3 mV
0.30
100
1.00 mV
1.00
or
0.5 mV
0.50
400
0.3 mV
0.30
CHANGE NO.5 Ipplies to III serial numbers.
Tlble5·1. Required Test Equipment should have the follow­
ing changes made:
a.
The AC Calibrator recommended model
should be a Fluke 5200A and 521 SA .
b.
The AC/DC Voltmeter recommended model
should be an -hp- Model 3466.
c.
The DC Standard recommended model
should be a Systron Donner Model
d .
The Voltmeter Calibrator should b e deleted
from the table.
Page 5·2. Figure 5·1. Accuracy Test Setup, should be altered
to show the use of the Fluke 5200A ACk Calbrator rather
than the -hp-Model 745A .
Plge 5·4. Figure 5·2. Accuracy and Frequency Response
Test Setup, should be altered to show the use of the
Systron Donner Model M 107 DC Standard rather than
the -hp- Model 740A.
Pege 5·1 1 . Figure 5·2. Delete paragraphs 5-45. 5-46, and
5-47.
Plge5·12. Delete Figure 5-5. Alternate Calibration and Fre­
quency Test Setup.
25 June 1984
(hp] MANUAL CHANGES
-hp- MODEL 400E/EL
AC VOLTMETER
Manual Part Number 00400-90020
Table
5-3.
Calibration
Table Me 1.
Meter (mV)
DC Output
of rllding)
(Volts)
±
±
±
5%
1.00
0.05
±
7.6%
0.50
0.038
±
±
10.8%
0.3 0
0.033
±
±
±
1%
1.00
0.02
±
0.50
0.015
2%
±
±
3.3%
0.30
0.013
±
±
1%
1.00
0.005
±
±
±
2%
0.50
0.0045
±
3.3%
0.3 0
0.0043
M
1 07 A
1 Millivolt Rlngl Only
Frequlncy
1%
(Hz)
Voltlge
Meter (mV)
Input
of reading)
100 k
1.00 mV
1 .00
0.5 mV
0.50
0.3 mV
0.30
500 k
1.00 mV
1.00
0.3 mV
0.30
4 M
1.00 mV
1.00
0.3 mV
0.30
ERRATA
Plge &·3. Tlbll &·3 IRepllceable PlrtS). Change the -hp- Part
Number of the A 1 Assembly from "00400-66521" to
"00400-66522" .
CHANGE NO. &. 400E: Applies to Seriel Numbers 1208A28944 Ind
Above.
4{JOEL: Applies to Serill Numbers 1208A29014 Ind
Above.
Section JVI, Tlble &·3 (Repllceable PlrtS). Do the following
changes in the table:
A.f.
-hp- Plrt
Des.
IUlll b er
A2C47
0180-0100
Add 4.7/AF 3 5V
Add SM4713 PNP
A2Q17
1853-0010
A2Q18
1855-0093
Add F17 48 N
A2R76
0683-1 045
Add lOOK
A2R77·
0757-027 4
Add 1 . 1 2K
A2R77"
0698-3 700
Add 7 15
A2R77·
0698-0 4 1 0
A d d 301
A2R78
0698-3458
Add 348K
Section VII. Figurl 7-1 (400 EIEL Schlmetic Dilgrlm Ind locltion
of Componlnts). Do the following changes in the figure.
Change the Meter Bridge to the bridge shown in Figure
C-1.
Change the component locator of the A2 Assembly (-hp­
Part Number 00400-66521) to the one shown in Figure
C-2.
Supplement A for 00400-90020
DC Output
(Volts)
±
±
±
1%
1.00
0.005
±
±
2%
0.50
±
0.0045
3.3%
0.30
0.0043
±
±
±
1 %
1.00
0.02
±
0.30
0.013
3.3%
±
±
±
5%
1.00
0.05
±
10.8%
0.30
0.033
Oescrlplion
Capacitor
Transistor
Channel
ohms
Resistor
JFET
ohms
Resistor
5% 1/ 4W
ohms
Resistor
1 % 1/8W
ohms
Resistor
1 % 1/8W
ohms
Resistor
1 % 1/8W
1 % 1/8W