1. Introduction SUND is a range of solar pumps for the circulation and filtering of pool water. It guarantees: Energy saving thanks to photovoltaic energy supply and variable-speed operation. Quick return on investment. Lengthening of system life and greater system reliability. ...
2. Safety Instructions The manufacturer strongly suggests carefully reading this operation manual before using and installing its products Any operation (installation, maintenance and repair) must be carried out by trained, skilled, and qualified personnel. Failure to observe and follow the instructions in this manual may result in dangerous and potentially lethal results. Pay attention to all standard safety and accident prevention regulations.
Devices marked with this symbol cannot be disposed of in household waste but must be disposed of at appropriate waste drop-off centres. It is recommended to contact the Waste Electrical and Electronic Equipment drop-off centres (WEEE) in the area. If not disposed of properly, the product can have potential harmful effects on the environment and on human health due to certain substances present within.
3.2 Weight and dimensions Net weight Packing Total dimensions weight Model 10,7 535x240x350(h) 11,4 SUND 50 3.3 Cable entries Model M20 cable gland M12 cable gland EMC clips SUND 50 Use the EMC clips to ground the signal cable shield. 4.
4.2 Electric connections Power supply AC: L(L1), N(L2), P.E. DC: L(L1), N(L2), P.E. In the case of DC power supply it is not necessary to respect the polarity. Connect only one power source (AC or DC) at a time. It is recommended to use pre-insulated female faston terminals 6,3x0,8 mm.
Page 8
Motor output U (red), V (black), W (blue), P.E. Respect the correspondence of colors and phases to ensure the correct rotation sense. Failure to comply with this recommendation will result in a drastic reduction in performance and possible damage to the pump itself. Analog inputs (sensors) ...
Page 9
Digital inputs • IN1 : motor start / stop • IN2 : motor start / stop or set value 1 - 2 switching* * only when “control mode: constant value 2 values” is selected. It is recommended to use only volt free contacts. Digital inputs can be configured as Normally Open or Normally Closed by software.
4.2.1 Protections The necessary protections depend on the type of installation and the local regulations. In the case of both DC and AC power supply, it is necessary to provide the safety protections for both DC side and AC side. For the DC side it is recommended to use a DC switch with current protection (fuses) and surge protection (surge arrestor).
5. Use and programming The pump can be operated in a basic way through the included keyboard. Stand-by red led Red led ON: unit is powered with correct input voltage Blinking red led: undervoltage Motor running Green led ON: motor is running green led Green led OFF: motor is stopped When the units is on “constant value”...
In order to access to parameters monitoring and programming it is necessary to use a smartphone or tablet with Bluetooth 4.0 (BTLE) and Nastec NOW App installed. The App is available on Android or iOS and can be downloaded free of charge through the on-line stores.
5.1.2 Programming Parameters are organized in four main menus: CONTROL, MOTOR, IN/OUT, CONNECT. Parameters are password protected in 2 levels of access: Installer level (CONTROL, IN/OUT). Password: 001 Advanced level (MOTOR, CONNECT). Password: 002 IN/OUT PARAMETERS Parameter Default Description Unit Unit [bar,%,ft,in,cm,m,K,F,C,gpm,l/min,m3/h,atm,psi]...
Page 14
Parameter Default Description Dig. input 1 manual reset Enabling or disabling digital input 1 manual reset. Disable Enable / Disable Dig. input 2 manual reset Enabling or disabling digital input 2 manual reset. Disable Enable / Disable Dig.In.2 delay Digital input IN2 delay. Digital input IN1 has 1 second fix delay.
Page 15
Parameter Default Description Set value Set value to be kept constant. XXX.X [bar] Value compensation at the maximum Compensation frequency for each pump. Acting on the green button you can reverse the XXX.X [bar] sign. Set value 2 ...
Page 16
Parameter Default Description Operating freq. 2 Frequency value to feed the pump. XXX [Hz] Freq.min.control Minimum frequency below which the pump tries to stop. XXX [Hz] Stop delay Delay for which the pump tries to stop below freq.min.control.
Page 17
Parameter Default Description MPPT: freq. gap MPPT frequency gap. df = XX.X [Hz] Kp and Ki parameters allow the dynamic control of system; set values are usually enough to get a valid dynamic control. COMBO Enabling or disabling COMBO ...
Page 18
Parameter Default Description Dry run cosphi Cosphi value below which the unit 0.65 stops the motor and give “no water” X.XX alarm. Restarts delay Restart delay after a dry running alarm.
6. Protections and alarms ALARM MESSAGE LED NOTIFICATION ALARM DESCRIPTION POSSIBILE SOLUTIONS Check possible causes of UNDER VOLTAGE Red STAND-BY led blinking Supply voltage too low undervoltage. Red STAND-BY led and Check possible causes of OVER VOLTAGE Supply voltage too high yellow ALARM led blinking overvoltage.
Page 20
Decrease the ramp-up time The current drawn by the Check the voltage drop load exceeds the capacity of IGBT TRIP ALARM Yellow ALARM led 5 blinks along the supply cable to of the inverter or power the motor. module (IGBT) is failed.
Page 21
EC DECLARATION OF CONFORMITY In according with: 2014/53/EU Radio Equipment Directive (RED) 2011/65/EU - RoHS Directive We, Nastec srl, via della Tecnica, 8, 36021, Barbarano Mossano, Vicenza, Italy, declare that: SUND conforms to the following regulations: EN 61000-6-3:2007 + A1:2011 EN 62233:2008...
Page 24
Copyright NASTEC srl Nastec reserves the right to modify informations in this manual without any notice. Nastec srl, Via della Tecnica, 8, 36021, Barbarano Mossano, Vicenza, Italy, Tel. +39 0444 886289, Fax +39 0444 776099, www.nastec.eu, info@nastec.eu...