Nastec SUND Series Installation And Use Manual

Solar pool pump

Advertisement

Quick Links

Installation and use manual
SUND
manSUND_eng_00

Advertisement

Table of Contents
loading

Summary of Contents for Nastec SUND Series

  • Page 1 Installation and use manual SUND manSUND_eng_00...
  • Page 2: Table Of Contents

    Index 1. Introduction ..................................3 2. Safety Instructions ................................4 3. Technical Characteristics ..............................5 3.1 Performance .................................... 5 3.2 Weight and dimensions ................................6 3.3 Cable entries .................................... 6 4. Installation ..................................6 4.1 Hydraulic connections ................................6 4.1.1 Priming ..................................6 4.2 Electric connections .................................
  • Page 3: Introduction

    1. Introduction SUND is a range of solar pumps for the circulation and filtering of pool water. It guarantees:  Energy saving thanks to photovoltaic energy supply and variable-speed operation.  Quick return on investment.  Lengthening of system life and greater system reliability. ...
  • Page 4: Safety Instructions

    2. Safety Instructions The manufacturer strongly suggests carefully reading this operation manual before using and installing its products Any operation (installation, maintenance and repair) must be carried out by trained, skilled, and qualified personnel. Failure to observe and follow the instructions in this manual may result in dangerous and potentially lethal results. Pay attention to all standard safety and accident prevention regulations.
  • Page 5: Technical Characteristics

    Devices marked with this symbol cannot be disposed of in household waste but must be disposed of at appropriate waste drop-off centres. It is recommended to contact the Waste Electrical and Electronic Equipment drop-off centres (WEEE) in the area. If not disposed of properly, the product can have potential harmful effects on the environment and on human health due to certain substances present within.
  • Page 6: Weight And Dimensions

    3.2 Weight and dimensions Net weight Packing Total dimensions weight Model 10,7 535x240x350(h) 11,4 SUND 50 3.3 Cable entries Model M20 cable gland M12 cable gland EMC clips SUND 50 Use the EMC clips to ground the signal cable shield. 4.
  • Page 7: Electric Connections

    4.2 Electric connections Power supply  AC: L(L1), N(L2), P.E.  DC: L(L1), N(L2), P.E. In the case of DC power supply it is not necessary to respect the polarity. Connect only one power source (AC or DC) at a time. It is recommended to use pre-insulated female faston terminals 6,3x0,8 mm.
  • Page 8 Motor output  U (red), V (black), W (blue), P.E. Respect the correspondence of colors and phases to ensure the correct rotation sense. Failure to comply with this recommendation will result in a drastic reduction in performance and possible damage to the pump itself. Analog inputs (sensors) ...
  • Page 9 Digital inputs • IN1 : motor start / stop • IN2 : motor start / stop or set value 1 - 2 switching* * only when “control mode: constant value 2 values” is selected. It is recommended to use only volt free contacts. Digital inputs can be configured as Normally Open or Normally Closed by software.
  • Page 10: Protections

    4.2.1 Protections The necessary protections depend on the type of installation and the local regulations. In the case of both DC and AC power supply, it is necessary to provide the safety protections for both DC side and AC side. For the DC side it is recommended to use a DC switch with current protection (fuses) and surge protection (surge arrestor).
  • Page 11: Use And Programming

    5. Use and programming The pump can be operated in a basic way through the included keyboard. Stand-by red led Red led ON: unit is powered with correct input voltage Blinking red led: undervoltage Motor running Green led ON: motor is running green led Green led OFF: motor is stopped When the units is on “constant value”...
  • Page 12: Monitoring And Programming

    In order to access to parameters monitoring and programming it is necessary to use a smartphone or tablet with Bluetooth 4.0 (BTLE) and Nastec NOW App installed. The App is available on Android or iOS and can be downloaded free of charge through the on-line stores.
  • Page 13: Programming

    5.1.2 Programming Parameters are organized in four main menus: CONTROL, MOTOR, IN/OUT, CONNECT. Parameters are password protected in 2 levels of access:  Installer level (CONTROL, IN/OUT). Password: 001  Advanced level (MOTOR, CONNECT). Password: 002 IN/OUT PARAMETERS Parameter Default Description Unit Unit [bar,%,ft,in,cm,m,K,F,C,gpm,l/min,m3/h,atm,psi]...
  • Page 14 Parameter Default Description Dig. input 1 manual reset Enabling or disabling digital input 1 manual reset. Disable Enable / Disable Dig. input 2 manual reset Enabling or disabling digital input 2 manual reset. Disable Enable / Disable Dig.In.2 delay Digital input IN2 delay. Digital input IN1 has 1 second fix delay.
  • Page 15 Parameter Default Description Set value    Set value to be kept constant. XXX.X [bar] Value compensation at the maximum Compensation  frequency for each pump. Acting on the green button you can reverse the XXX.X [bar] sign. Set value 2 ...
  • Page 16 Parameter Default Description Operating freq. 2  Frequency value to feed the pump. XXX [Hz] Freq.min.control    Minimum frequency below which the pump tries to stop. XXX [Hz] Stop delay    Delay for which the pump tries to stop below freq.min.control.
  • Page 17 Parameter Default Description MPPT: freq. gap  MPPT frequency gap. df = XX.X [Hz] Kp and Ki parameters allow the    dynamic control of system; set values are usually enough to get a valid dynamic control. COMBO Enabling or disabling COMBO ...
  • Page 18 Parameter Default Description       Dry run cosphi Cosphi value below which the unit 0.65 stops the motor and give “no water” X.XX alarm.       Restarts delay Restart delay after a dry running alarm.
  • Page 19: Protections And Alarms

    6. Protections and alarms ALARM MESSAGE LED NOTIFICATION ALARM DESCRIPTION POSSIBILE SOLUTIONS Check possible causes of UNDER VOLTAGE Red STAND-BY led blinking Supply voltage too low undervoltage. Red STAND-BY led and Check possible causes of OVER VOLTAGE Supply voltage too high yellow ALARM led blinking overvoltage.
  • Page 20  Decrease the ramp-up time The current drawn by the  Check the voltage drop load exceeds the capacity of IGBT TRIP ALARM Yellow ALARM led 5 blinks along the supply cable to of the inverter or power the motor. module (IGBT) is failed.
  • Page 21 EC DECLARATION OF CONFORMITY In according with: 2014/53/EU Radio Equipment Directive (RED) 2011/65/EU - RoHS Directive We, Nastec srl, via della Tecnica, 8, 36021, Barbarano Mossano, Vicenza, Italy, declare that: SUND conforms to the following regulations: EN 61000-6-3:2007 + A1:2011 EN 62233:2008...
  • Page 22 NOTES...
  • Page 24 Copyright NASTEC srl Nastec reserves the right to modify informations in this manual without any notice. Nastec srl, Via della Tecnica, 8, 36021, Barbarano Mossano, Vicenza, Italy, Tel. +39 0444 886289, Fax +39 0444 776099, www.nastec.eu, info@nastec.eu...