Download Print this page
Black Box ME742A-R3 Quick Start Manual
Black Box ME742A-R3 Quick Start Manual

Black Box ME742A-R3 Quick Start Manual

Advertisement

Quick Links

S7
RXB
RXA
TXB
TXA
A B C D E
DB25
Female
Conn.
S6
ON
TRANSMIT
CLOCK
OFF
1 2 3 4
SELECT
SPECIFICATIONS:
Terminal Interface: EIA RS-232-C configured as DCE serial synchronous internal/external/
recovered TX data clock.
Line Interface: EIA-RS-485 twisted pair (26 AWG minimum), DC continuity required.
Connectors: (1) DB25 female-RS-232 port; (1) four-wire terminal block (TB1)-RS-485 port.
Operation: Point-to-Point or Multi-point; Full- or Half-Duplex Transparent to data. Selectable
RTS-to-CTS delay, DTE or DCE configurable RS-232 port, Normal or loopback
operation.
Timeout Delay: 1 msec, 100 msec, or 1 sec. (for the RS-485 driver enabled by data feature)
Pins Supported: RS-232 port: TD,RD, RTS, CTS, CD, DTR, DSR, SG, TC RC, DTE timing,
AND FG;
RS-485 port: TXA, TXB, RXA, RXB
Operating Modes: 2-wire half duplex, 4-wire full or half duplex point-to-point or multipoint,
Normal or line/digital loopback; Constant Carrier or Switched Mode.
Data Rate: 1200, 2400, 4800, 9600, 19200, 38400, 56000, 64000, 112000, or 128000 bps.
RTS/CTS Delay: 0, 11, 50, or 160 msec.
Indicators: (5) LED's: TX, RX, RTS, CD and PWR.
Power: Input - 115 VAC, 60 Hz, 8.5 watts. Output - 17 VAC CT, 700 ma.
Power Supply part # PS154
S5
ON
1 2 3 4 5 6 7 8
OFF
S4
W3
ON
BAUD RATE
SETTINGS
1 2 3 4
OFF
Half
Full
TST
LLB
DLB
ME742A-R3
SPEED
1200 bps
2400 bps
4800 bps
9600 bps
19,200 bps
38,400 bps
56,000 bps
64,000 bps
112,000 bps
128,000 bps
Power
The RS-232 Synchronous Multipoint Line Driver provides short haul synchronous data communication over customer-
owned twisted-pair cable. The Line Driver is available as a standalone (Part Number ME742A-R3) or a rackmount card
(Part Number ME742C-R3). The rackmount version is functionally identical to the standalone unit. The card can be
installed in a rackmount chassis that holds up to 16 cards (Part Number RM005).
RD
The Line Driver has an RS-232 port (configured as DCE) that connects to a host computer or terminal (DTE), and a 4-
screw terminal block for RS-485 communication over a 2- or 4-wire line. Transmission can be two-wire half-duplex, or
TD
four-wire half- or full-duplex. There are a variety of switch-selectable baud rates ranging from 1200 to 128000 bps.
A group of LED's on the unit's front panel indicate flow control status (TX, RX, RTS, CD). Three push-buttons on the
front panel are used to perform line and digital loopback testing.
CD
or jumpers.
RTS
Proceed as follows to install to Line Drivers:
1. Configure the Line Driver to suit your particular application.
2. To verify that the Line Driver is functioning correctly, power on the unit and perform the Line Loopback Test.
Repeat this procedure for each unit in your configuration.
3. Power down the unit. Connect the Line Driver to the RS-485 line via the 4-screw terminal block on the unit's
rear panel.
4. To verify the communications link, power on the unit and perform the Digital Loopback Test.
5. Power off the unit. Connect the DTE to the Line Driver's DB25 connector via an RS-232 cable.
6. If desired, power on the unit and perform the End-to-End Continuity Test to verify the integrity of each
segment of the link. This test allows you to isolate a defective circuit.
The figure above shows a layout of the printed circuit board and the location of the jumpers and switches.
Switches:
Three options are user-configurable via the internal switches:
1. Baud Rate
2. Transmit Data Clock
3. Node Termination
Baud Rate:
Ten switch-selectable data rates are available: 1200, 2400, 4800, 9600 (factory setting), 19200, 38400, 56000, 64000,
112000, or 128000 bps.
DISTANCE
The maximum transmission distance is dependent on the data rate selected. The typical range for data transmission is 4
miles at 1200 bps and .35 miles at 12000 bps. Refer to the table to the left for baud rates and maximum transmission
4 mi. (6.4 km)
distances.
3 mi. (4.8 km)
2.3 mi. (3.7km)
Transmit Data Clock:
Data timing is synchronized among all connected devices in one of three ways:
1.7 mi. (2.7km)
1. Internal Clock (factory setting)
2. Recovered Clock
1.2 mi. (1.9km)
3. External Clock
Internal Clock- Line Driver generates transmit data clock and presents clock to attached DTE via
.9 mi. (1.4km)
Recovered Clock- Transmit data clock is presented to the DTE on Pin 15, synchronized with timing of
.8 mi. (1.2 km)
.75 mi. (1.2km)
External Clock- Clocking is determined by local DTE. The clock is presented to the Line Driver on
.55 mi. (.88km)
.35 mi. (.56km)
INTRODUCTION:
A number of options are configurable via internal switches
INSTALLATION:
Configuring Your Unit:
Note:
The baud rate should be set to match
the rate of the attached DTE.
Pin 15. The DTE then presents synchronized data to the Line Driver on Pin2.
data received from the remote device. The DTE then presents synchronized data
to the Line Driver on Pin 2.
Pin 24, and returned to Pin 15. The DTE then presents synchronized data to the Line
Driver on Pin 2.

Advertisement

loading

Summary of Contents for Black Box ME742A-R3

  • Page 1 The RS-232 Synchronous Multipoint Line Driver provides short haul synchronous data communication over customer- owned twisted-pair cable. The Line Driver is available as a standalone (Part Number ME742A-R3) or a rackmount card (Part Number ME742C-R3). The rackmount version is functionally identical to the standalone unit. The card can be 1 2 3 4 5 6 7 8 installed in a rackmount chassis that holds up to 16 cards (Part Number RM005).
  • Page 2 BAUD RATE SETTINGS (SWITCHES 4 AND 5) Node Termination: BAUD Switch 4, Position Switch 5, Position The user can select whether or not the termination network for the receiver is connected to the line. Terminating the devices on the extreme ends of the line reduces distortion and improves overall signal quality in RATE most applications.
  • Page 3 4-WIRE POINT-TO-POINT APPLICATION 4-WIRE POINT-TO-MULITPOINT APPLICATION MASTER SLAVE SLAVE...
  • Page 4 2-WIRE POINT-TO-POINT APPLICATION 2-WIRE POINT-TO-MULITPOINT APPLICATION MASTER SLAVE SLAVE...