U-Line Modular 3000 Series User Manual & Service Manual page 62

36" beverage center
Hide thumbs Also See for Modular 3000 Series:
Table of Contents

Advertisement

USER GUIDE
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Evaporator Thermistors
If an evaporator thermistor fails the unit will rely on a
preset defrost timer during defrost cycles. The unit will
otherwise operate normally. Refer to defrost section.
Ambient Thermistor
If the thermistor fails the unit will operate normally.
Thermistor Resistance Data
Temp (F)
Temp (C)
-40
-40
-31
-35
-22
-30
-13
-25
-4
-20
5
-15
14
-10
23
-5
32
0
41
5
50
10
59
15
68
20
77
25
86
30
95
35
104
40
113
45
122
50
131
55
140
60
149
65
158
70
167
75
176
80
* (+/-5%)
Nominal Resistance
(OHMS)*
169157
121795
88766
65333
48614
36503
27681
21166
16330
12696
9951
7855
6246
5000
4029
3266
2665
2186
1803
1495
1247
1044
879
743
631
62
u-line.com
Thermistor 2

Advertisement

Table of Contents
loading

This manual is also suitable for:

3036bvwc

Table of Contents