Bogen SERIES 15 Manual page 14

Table of Contents

Advertisement

TO TURN CONSOLETTE ON
Set
POWER ON-OFF switch to ON position.
DISTRIBUTE MICROPHONE
PROGRAM
Move
program output switch to SET position. De-
press MIC function switch. Select microphone level with
MIC fader control knob according to control panel
speaker volume and/or reading on PROGRAM LEVEL
output meter. When appropriate level is reached, dis-
tribute program by moving program output switch to
SEND position. Select either NORM for Switchbank
control over distribution or ALL for distribution to all
stations not connected to the intercom. (May be used in
conjunction with PROGRAM level control for program
mixing).
TO DISTRIBUTE RADIO/PHONO-TAPE
PROGRAM
Move program output switch to SET position. De-
press PROG function switch. Select level of radio/
phono/tape program with PROGRAM fader control
knob according to control panel speaker volume and/or
output meter reading. Distribute program by switching
program output to SEND position.
To distribute output from a tape recorder, connect
the 2-conductor phone plug from the tape recorder to
PE IN jack on the control panel and follow pro-
re outlined above. Phonograph input will be auto-
matically disconnected.
TO OPERATE ALL-CALL FUNCTION
Move program output switch to SEND position.
Move program distribution switch to ALL position.
Program is transmitted to all stations regardless of posi-
tion of station selector switches. (Note: Disconnect in-
tercom function; stations connected to the intercom will
not be affected).
TO COMMUNICATE WITH SELECTED
STATIONS
TO SEND. Depress INTERCOM function switch.
Select station to be contacted on switchbank panel.
Depress TALK/LIST switch to send; release switch to
Intercom level control should always be left at
monitor.
the setting for normal transmission to room speakers.
(Note: does not affect program distribution to other
stations).
TO RECEIVE. If a voice call-in system is installed,
the station operator makes contact over the intercom
annel via the station speaker and CA-13 call switch,
identifies his or her station. To respond to call,
station on switchbank and depress TALK/LIST
switch. Speak clearly into the control panel speaker
from a distance of approximately 12" (Note: Intercom
function switch must be depressed to receive VOICE
CALL IN from stations).
TO OPERATE EMERGENCY
Depress EMERG switch and speak clearly into panel
speaker. Message is transmitted to all stations regardless
of switchbank settings, program and intercom function
settings, and position of POWER ON-OFF switch.