Initialization Pulse Adjust; Printed Circuit Board) Remove - Panasonic TH-50PHD8UK Service Manual

High definition plasma display
Hide thumbs Also See for TH-50PHD8UK:
Table of Contents

Advertisement

TH-50PHD8UK
9.2.

Initialization Pulse Adjust

1. Input a white signal to plasma video input.
2. Set the picture adjustment items as follows.
· Picture menu : Standard
· Color temperature : Normal
· Picture : 25
· Aspect : Full
3. Connect Oscilloscope to TPSC1 (T1) and check for 20 ± 15µ Sec.
4. Connect Oscilloscope to TPSC1 (T2) and adjust VR6602 for 155 ± 10µ Sec.
9.3.
P.C.B. (Printed Circuit Board) Remove
9.3.1.
Caution
1. To remove P.C.B. , wait 1 minute after power was off for discharge from electrolysis capacitors.
9.3.2.
Quick adjustment after P.C.B. Remove
P.C.B.
P Board
SC Board
SS Board
D, J Board
*See the Panel label.
Caution:
Absolutely do not reduce Vsus below Ve not to damage the P.C.B.
Test point
T1
TPSC1 (SC)
T2
TPSS1 (SS)
Name
Test Point
Vsus
TPVSUS
Vad
TPVAD
Vscn
TPVSCN
Vset
TPVSET
Ve
TPVE
Vda
TPVDA
White balance, Pedestal and Sub brightness for NTSC, PAL, HD, PC and 625i signals
Volume
Fixed
20 ± 15µ Sec
VR6602(SC)
155 ± 10µ Sec
Voltage
176V ± 2V
VR351 (P)
-90V ± 1V
VR6801 (SC)
Vad+ 130V ± 4V
Fixed
225V ± 7V
Fixed
150V ± 1V
VR6250 (SS)
75V ± 1V